White Paper Using A Specification Library For Humidification Projects

Extrait du fichier (au format texte) :

WHITE PAPER

USING A SPECIFICATION LIBRARY FOR
HUMIDIFICATION PROJECTS
EXECUTIVE SUMMARY
Architects, designers and other specifiers use 3-D models from product manufacturers  files that contain all the relevant data needed to make a decision about a building product. It's critical that these specifiers have access to online tools that allow them to research products and connect with building product manufacturers.
With more government agencies requiring traceability in building design, including access to the details of the equipment used, these models allow specifiers to provide this information and prove their accountability.
BIM content for all DriSteem's humidification systems are available for download online at a number of provider sites including SpecifiedBy, BIMobject, and ARCAT  delivering the fastest, simplest way to find and compare products during the research process.
These sites provide not only REVIT and other digital resources, but also specifications and other equipment details.
BIM adoption varies by country and by project type. The earliest adoption and largest adoption of BIM
is in the UK followed by Germany, Poland and France.

DriSteem Ultra-sorb® LV steam dispersion panel

1

INCORPORATING HUMIDIFICATION INTO DESIGNS
Importance of Humidification in Building Design
Proper humidification is extremely important for many applications and must be considered up front during the building design process. Factors to consider include the intent (humidification or cooling), the humidification load, available energy sources, quality of the supplied water, where the moisture will be dispersed, and the level and type of controls needed.
Failure to consider all factors may result in a system that operates inefficiently, doesn't meet the intended requirements, or can cause unintended consequences due to poorly managed moisture. With a good design, properly controlled humidification can promote health and safety, improve productivity, extend the life of materials, and enhance occupant satisfaction.
Here are some common uses of humidification:
"

Indoor Air Quality: Studies have shown that the optimum range for relative humidity (RH) is between 40-60%. Bacteria and viruses thrive in dry air where the relative humidity is less than 40%. Keeping the relative humidity under 60%
hinders the development of fungi, mites, and chemical interactions. Proper humidification can reduce occurrences of allergic rhinitis, respiratory infections, and asthma, which in turn reduces absenteeism.

"

Material Preservation: Many building materials, finishes,
furnishings, and artifacts are hygroscopic, meaning they

Dans la boutique



Wts Handbk En
Wts Handbk En
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WATER FUNDAMENTALS HANDBOOK First Edition ii DRISTEEM WATER FUNDAMENTALS HANDBOOK Water Fundamentals Handbook First Edition Steve Felber DRISTEEM WATER FUNDAMENTALS HANDBOOK iii Copyright © 2017 by DRI-STEEM Corporation All rights reserved. No part of this publication may be reproduced or transmitted, in any form or any means, without the written permission of the company. Printed and bound in the United States of America. First printing September 2017. DRI-STEEM Corporation 14949 Technology...

Whitepaper Ultra Sorb Xv 0723
Whitepaper Ultra Sorb Xv 0723
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Humidification for pressurized steam applications: Short absorption and energy savings with pressurized condensate return As commercial and industrial steam humidification systems grew in complexity and demand since the mid 1900s, unique application requirements inspired 50 years of innovation. But each new breakthrough required new trade-offs: Non-jacketed steam dispersion tubes were efficient and easy to install; however, their steam absorption distances were too long for some applications, and...

White Paper Evaporative
White Paper Evaporative
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Evaporative cooling and humidification High-pressure water atomized, reduces cooling load and energy costs by Dave Schwaller, Mechanical Engineer DriSteem Corporation, Eden Prairie, MN Evaporative high-pressure systems are used to cool and humidify air for processes, products, preservation, and comfort. These flexible systems can be installed in airstreams or directly in the space to be conditioned. They use very little electrical energy to operate and can be located long distances from the air...

High Pressure System Data Center Case Study
High Pressure System Data Center Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
High-pressure system case study Data center humidification and cooling DriSteem system reclaims water from air handlers while it humidifies and cools a data center RESULTS " Maintains constant minimum humidity levels in a 130,000-square-foot server room with 35-foot ceilings " Reduces the building's cooling load by over 200 tons at peak demand " Reprocesses drain water from air handlers while producing no wastewater GUARANTEED SITE CONDITIONS This data center* provides colocation services, where...

Whyhumidify
Whyhumidify
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WHY HUMIDIFY? " Improve indoor air quality " Improve manufacturing processes OPTIMUM RELATIVE HUMIDITY RANGE FOR A HEALTHY ENVIRONMENT Optimum range " Preserve materials and furnishings Bacteria " Improve comfort for building occupants Viruses Fungi Properly controlled humidification enhances occupant health and comfort, improves manufacturing processes, and helps preserve building materials and furnishings. In short, any building housing people or things will benefit from proper humidification,...

Humidification Handbook
Humidification Handbook
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
HUMIDIFICATION HANDBOOK Fifth Edition 2 DRISTEEM HUMIDIFICATION HANDBOOK Humidification Handbook FIFTH EDITION BERNARD W. MORTON AND DRI-STEEM CORPORATION DRISTEEM HUMIDIFICATION HANDBOOK 3 Copyright © 2019 by Bernard W. Morton and DRI-STEEM Corporation All rights reserved. No part of this publication may be reproduced or transmitted, in any form or any means, without the written permission of the company. Printed and bound in the United States of America. First printing June 1998. DRI-STEEM...

New Balance Sports Research Lab Case Study
New Balance Sports Research Lab Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
ENVIRONMENTAL CHAMBER PROVIDES ON-DEMAND CONDITIONS YEAR ROUND New Balance Sports Research Lab BOSTON, MA One of the most prominent brands in Boston Landing is New Balance. The neighborhood is home to the company's world headquarters, two retail stores, a fitness club, the TRACK at New Balance, and the New Balance Sports Research Lab. Measuring and improving performance The New Balance Sports Research Lab is equipped with 3D dynamic motion capture arrays and force plates that record athletes'...

Whitepaper Reducing Energy Use Airstream Heat Gain And Condensate Production
Whitepaper Reducing Energy Use Airstream Heat Gain And Condensate Production
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Steam humidification: Reducing energy use, airstream heat gain, and condensate production Updated! Includes analysis of stainlesssteel-shielded dispersion tubes. by Lynne Wasner and Jim Lundgreen, Senior Mechanical Design Engineer DRI-STEEM Corporation Enlightened building owners demand accountability for every resource consumed in the construction and operation of new or renovated buildings. Meeting conservation benchmark standards requires measurable building performance, for it is commonly...
 

STULZ CyberRow Brochure 0211 it
STULZ CyberRow Brochure 0211 it
09/04/2011 - www.stulz.com
IT Cooling Solutions CyberRow Controllo intelligente della portata d'aria  per un raffreddamento più efficiente dei rack Una nuova direzione per la climatizzazione dei rack Un'idea innovativa per garantire un controllo preciso di temperatura e umidità e sistemi ICT affidabili  CyberRow di STULZ Esistono varie soluzioni per la climatizzazione di un data centre e ognuna di queste può consentire il raggiungimento di questo obiettivo. Per garantire risultati ottimali, offriamo una gamma completa...

biblio-65-1076
biblio-65-1076
09/04/2011 - www.pierrebleuebelge.be
er was eens uw tuin Foto van de voorpagina : Tuinen van het Hines gebouw - Neuilly sur Seine. Realisatie : Pascal Gasquet. Landschapsarchitect Er was eens een steen die al eeuwenlang de grootste ontwerpers wist te bekoren. Een steen die perfect harmonieert met de natuur. Een steen die in de loop van de dag van uitstraling en textuur verandert. Een steen die zich naadloos inpast in elke tuin en die mettertijd alsmaar mooier wordt. Doorblader deze brochure en ontdek wat Belgische Blauwe Hardsteen...

Flyer Orizonamporizon Store Orizon 1
Flyer Orizonamporizon Store Orizon 1
10/07/2024 - www.tellier-g.fr
PORTE ACCORDEON ORIZON ORIZON + Résistance à l'effraction * PLAN DE COUPE PLAN DE COUPE Selon normes EN 1630 76 13 76 Ud "d 1,5* 59 13 59 131 165 Plus de Lumière - Plus de Clarté - Plus de Performances CARACTERISTIQUES COMMUNES Système accordéon porté au sol Store intégré (en option) Produit livré monté dormant/ouvrants, vitrages livrés séparément sur palettes Charnières invisibles avec système anti pince-doigt Accessoires Inox Verrouillage des vantaux intermédiaires par...

049 0039 NACELLE ELECTRIQUE 150AETJC
049 0039 NACELLE ELECTRIQUE 150AETJC
22/02/2012 - www.loxam.fr
Ce modèle est présenté à titre indicatif comme un exemple de matériel référencé dans cette catégorie. Il ne présage pas du matériel proposé dans l agence que vous aurez sélectionnée. 140 2080 NACELLE ELECTRIQUE 150 AETJ C 2000 1500 6050 NACELLE ELECTRIQUE 150 AETJ C Code produit 049 0039 Hauteur de travail 15 m Hauteur de plancher 13 m Déport maxi 7,60 m Charge maxi dans le panier 200 kg Bras articulé Oui Moteur Batteries Pente maxi

Porte cobalt Pts
Porte cobalt Pts
13/02/2012 - www.technal.fr
Cobalt : porte simple action blindée (PTs) - Applications : 10/03 04 - 1.1 63 45 4,5 Porte 1 vantail Porte 2 vantaux (ouverture vers l'intérieur) Porte 1 vantail Porte 2 vantaux (ouverture vers l'extérieur) - Elévation (échelle 1/20) : 85,5 1B 1A 1 A' 190 Largeur de passage porte 1 vantail : L - 269 mm L = largeur hors tout. 1 B' Porte 2 vantaux, ouverture vers l'extérieur (vue de l'extérieur) - Coupes (échelle 1/2) : 10 Coupe verticale 1 B - B' 63 PTs005R1G 135 85,5 4,5 45 Coupe...

Rector Norbat
Rector Norbat
19/06/2024 - www.andresudrie.com
Information presse Mars 2024 A Nordbat, RECTOR expose ses solutions de préfabrication béton bas carbone pour la construction et la rénovation des bâtiments Dans un contexte réglementaire encourageant la performance énergétique par la sobriété carbone des bâtiments, Rector, spécialiste de la fabrication d'éléments de plancher en béton précontraint et béton armé, murs et éléments de structure, s'engage depuis de longues années pour une construction durable. C'est donc tout naturellement...