Plaquette / Brochure

Extrait du fichier (au format texte) :

CHARGEUR DE BATTERIE (TÉLÉPHONIE/SÉCURITÉ) RECTIFIER BATTERY CHARGER (PABX)

Série JUPITER 500 JUPITER 500 Series

A U T O M A T I S M E S

E N E R G I E

E L E C T R O N I Q U E

S Y S T E M E S

ALIMENTATION A COURANT CONTINU CHARGEUR DE BATTERIE POUR : BAIES TÉLÉPHONIQUES (MOYENNE CAPACITÉ). ÉQUIPEMENTS SENSIBLES (RADIO, PROCESS). Conformité Normes CEM (Directive n° 89/336/CEE) : - faible réjection harmonique, - haute immunité. Appareil très complet avec de très nombreuses fonctionnalités (voir équipement). Conception simple : ROBUSTESSE. Compact / efficace. Capable de fournir un débit permanent important avec possibilité de pointes élevées.

DC POWER SUPPLY BATTERY CHARGER FOR : PABX (MEDIUM CAPACITY). SENSITIVE LOADS (RADIO, PROCESS). EMC compliance (Directive n ° 89/336/EEC ) : - low harmonic re-injection, - high immunity. Very complete product with many facilities (see features). Excellent design : ROBUST. Compact size/efficient. Able to supply high permanent current with high peak current capability.

CARACTÉRISTIQUES/TECHNICAL
REFERENCE TENSION NOMINALE CALIBRE CHARGEUR ENTRÉE SORTIE BATTERIE TENSION BATTERIE RÉGULATION TENSION BATTERIE LIMITATION COURANT BATTERIE SORTIE UTILISATION TENSION UTILISATION COURANT MAXI UTILISATION LIMITATION COURANT TOTAL FILTRAGE RENDEMENT* NORMES DIMENSIONS (HLP/mm)
J.16.24 16 A J.25.24 24 V 25 A J.30.24 30 A J.10.48 10 A J.16.48 16 A 230 Vca/Vac ± 15% - 50/60 Hz (47/63 Hz) Floating : 26,4 Vcc/Vdc ou / or 27 Vcc/Vdc (selectable) Charge rapide/Boost : 27,6 Vcc/Vdc/29,4Vcc/Vdc (ajustable)

DATA
J.25.48 48 V 25 A J.30.48 30 A

Floating : 52,8 Vcc/Vdc ou / or 54 Vcc/Vdc (selectable) Charge rapide/Boost : 55,2 Vcc/Vdc/58,8 Vcc/Vdc (ajustable) 20 secondes + mode manuel avec arrêt temporisé. Filtrage 80 mV (24 Vcc). Mise en parallèle de 3 chargeurs ou plus. Configuration "système" avec batterie et redresseurs montés dans une même armoire. Montage en Rack 19" Automatic boost charge after mains failure >20 seconds and manual mode with automatic stop. Ripple 80 mV (24 Vdc). Paralleling of 3 chargers or more. "System " configuration with battery and rectifiers built in one cabinet. 19 inches Rack mounting.

AEES - Parc Technologique 259, allée Jacques Monod 69792 SAINT PRIEST cedex France - Tel. 33 (0) 472 47 63 77 - Fax. 33 (0) 478 40 13 94
Email: aees@aees.fr site : www.aees.fr

AUTOMATISMES

ENERGIE

ELECTRONIQUE

SYSTEMES

E

Dans la boutique



ALPHA J 36085fa
ALPHA J 36085fa
27/10/2010 - www.aees.fr
E énergie DC | DC energy Chargeur | Charger ALPHA J E applications / applications ALPHA J est un chargeur de batterie mural prêt à l'emploi, incorporant toutes les protections nécessaires. Associé à des batteries plomb ou Cadmium Nickel, il a pour mission de créer un courant continu pour sauvegarder votre installation. Les chargeurs ALPHA J possède toutes les fonctionnalités nécessaires à la charge des batteries plomb ou Cadmium Nickel afin de leur assurer la plus grande durée de vie....

Plaquette
Plaquette
27/10/2010 - www.aees.fr
E énergie DC Alimentation didactique Série MXF E applications Ces alimentations MXF basse tension (BT) sont spécialement conçues pour les salles de travaux pratiques des collèges, lycées ou universités des établissements publics ou privés. Elles délivrent une tension variable 0 - 30V non régulée alternative (Vac) ou continue (Vdc). La sélection de la tension est réalisée en toute sécurité par les utilisateurs par le biais d'un commutateur en face avant. Le réglage de la tension...

Plaquette / Brochure
Plaquette / Brochure
27/10/2010 - www.aees.fr
REDRESSEUR PROGAMMABLE SUPRAL PROGRAMMABLE RECTIFIER SUPRAL SUPRAL APPLICATIONS/APPLICATIONS Les redresseurs chargeurs SUPRAL sont conçus pour s'adapter très simplement à tout type d'applications industrielles. Ils s'intègrent facilement dans tous les équipements de contrôles commandes des processus de fabrication, des réseaux de transports électriques et de transmission de données. Ils fournissent à ces équipements l'énergie indispensable secourue ou non. Grâce à leur sélecteur...

FICHE PCCE 20208 definitive V2
FICHE PCCE 20208 definitive V2
27/10/2010 - www.aees.fr
E sources centralisées | luminaires | blocs autonomes PCCE PCCE PCCE est une source centrale pour l'alimentation des luminaires (LSC) de sécurité des Etablissements Recevant du Public (ERP) et/ou des Travailleurs (ERT). Sa gamme de puissances convient particulièrement aux établissements où le nombre de points lumineux est élevé, c'est-à-dire où les parties communes sont nombreuses ou très étendues. PCCE apporte à votre système d'éclairage de sécurité des rendements améliorés...

téléchargez le certificat
téléchargez le certificat
27/10/2010 - www.aees.fr
Page 1 / 2 Certificate number: SMS.W.II./856/A.0 www.veristar.com RECOGNITION FOR BV MODE II SCHEME AUTOMATISMES ENERGIE ELECTRONIQUE SYSTEMES (AEES) SAINT PRIEST - FRANCE Summary of the range of the recognition which is detailed in the subsequent page(s): Battery charger assemblies. This certificate is issued to attest that BUREAU VERITAS has performed, at the above company's request and in compliance with the requirements of NR320, a satisfactory assessment of the manufacturing facilities...

Certificat E 9997 3
Certificat E 9997 3
27/10/2010 - www.aees.fr
DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-9997 This Certificate consists of 3 pages This is to certify that the Constant Voltage Charger with type designation(s) CMV Holder of certificate Automatismes Energie Electronique Systèmes Saint Priest Cédex, France is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application Voltage output Power Temperature class Vibration class Humidity...

Téléchargez le certificat
Téléchargez le certificat
27/10/2010 - www.aees.fr
DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-9997 This Certificate consists of 3 pages This is to certify that the Constant Voltage Charger with type designation(s) CMV Holder of certificate Automatismes Energie Electronique Systèmes Saint Priest Cédex, France is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application Voltage output Power Temperature class Vibration class Humidity...

sources centralis”es 6H - AEES
sources centralis”es 6H - AEES
05/12/2017 - www.aees.fr
SOURCES CENTRALISEES 6 HEURES POUR E.R.P. AVEC LOCAUX A SOMMEIL PCC 30C-6H EPP 48 650-6H APPLICATION Les sources centralisées EPP à courant continu de 300W à 1,5kW et PCC à courant alternatif de 600VA à 4,5kVA autonomie 6 HEURES sont réglementairement préconisées pour l alimentation des installations d éclairage de sécurité des Etablissements Recevant du Public (E.R.P.) de toutes catégories avec locaux à sommeil ne disposant pas de source de remplacement à partir d un groupe...
 

T35100SL | Telescopic Handlers - Bobcat.eu
T35100SL | Telescopic Handlers - Bobcat.eu
09/12/2014 - www.bobcat.eu
T35100SL | Telescopic Handlers T35100SL | Specifications Load Charts With forks and TITAN 400/70 x 20 150B 166A2 LIFT RIGGER II (standard) or DUNLOP 400/70 x 20 150B 168A2 (option) tyres  on tyres 13 1 9 7 3500 kg 2000 kg 3000 kg 8 7 TITAN 400/70x20 150B 166A2 LIFT RIGGER II (4 bar front/ rear) 7.0 km/h 30.0 km/h Direct drive / soft drive 5 6 5 4 3 3 1500 kg 2 1000 kg 4 2


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

Système HTA®-E de Girpi pour évacuation gravitaire 100°C
Système HTA®-E de Girpi pour évacuation gravitaire 100°C
30/04/2012 - www.andresudrie.com
BP 36 - Rue Robert Ancel 76700 HARFLEUR Tél. : 02 32 79 60 00 Fax : 02 32 79 60 27 www.girpi.fr Information Presse Avril 2012 Systèmes complets pour le transport de l'eau chaude et de l'eau froide avec ou sans pression dans le domaine du bâtiment Système HTA®-E Evacuation gravitaire 100°C Evacuation des eaux grasses jusqu'à 100°C Développé par GIRPI, le HTA®-E est une solution professionnelle, performante et fiable, particulièrement adaptée à l'évacuation sans pression des eaux...

AL440 Articulated Loader Specifications
AL440 Articulated Loader Specifications
01/12/2010 - www.bobcat.eu
AL440 Articulated Loaders AL440 Machine Rating Specifications Speciûcations Lift breakout force (ISO 8313) Lift capacity (ISO 8313) Tipping load, straight (ISO 8313) Tipping load, articulated at 40° (ISO 8313) Make / Model Fuel / Cooling Power (97/68 EC) Power (ECE-R24) Torque at 1400 RPM (ISO 9249) Number of cylinders Displacement Fuel tank capacity Machine Rating Lift breakout Weights force (ISO 8313) Lift capacity (ISO 8313) Operating weight, standard Tipping load, straight (ISO 8313) Operating...

LiFéa : système de goulottes de distribution appareillables - Hager
LiFéa : système de goulottes de distribution appareillables - Hager
09/02/2012 - www.hager.fr
LiFéa : système de goulottes de distribution appareillables ribution un monde d'astuces pour vos chantiers Guide de choix Pièces de forme LFF 40090 Blanc Paloma 9010 : 852579 Gris 7030 : 852562 Supports d'appareillage M 2024 875189 Capacités Dim A x B : 40 x 90 cm Ø maxi : 32 mm Nbr de câbles 3 x 2,52 : 17 LFF 71H090 9010 : 868501 LFF 40093 9010 : 868006 7030 : 868013 LFF 71H099 9010 : 868518 colisage : sachet de 10p. LFF 40094 9010 : 868020 7030 : 868037 LFF 40095 9010 : 868044...

Download Katalog Info
Download Katalog Info
29/12/2010 - www.hettich.com
Aluminium-Rahmenprofil Breite 45 mm für Intermat 9924 T42/26 Fax-Bestellung an Ihren Fachhändler Einfach Fax ausfüllen und Sie bekommen einen komplett auf Ihr individuelles Maß konfektionierten Satz Aluminium-Rahmenprofile, Breite 45 mm Auf individuelle Maße konfektionierbar oder fertig konfektioniert Dieses Profil kann individuell selbst auf Maß konfektioniert werden. Fuge H bis 800 H bis 800 H bis 1500 H bis 1500 9,5 19 4+5 9,5 30 6 b b 8 b 37 b ø 26 max. 450 ø 2,5 c c ...