Photometrics data (PDF)

Extrait du fichier (au format texte) :

Luminaire Réf. LASY AC-1015 Nom LASY AC-1015 XENON 10W12V CL Archives AGABEKOV 2008 Rendement Valeur Maximum 100.00% 2062.07 cd/klm Long. Long. 0.062075 m2 0.000000 m2 0.000000 m2 Asymétrique 6.47

Mesure Réf. CLF1414/08-20L Nom LASY AC-1015 XENON 10W12V CL Date 04-09-2008 Syst. de Coordonn. Position 1015 mm 955 mm C-G C=330.00 G=38.00 Larg. Larg. 120 mm 65 mm

Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut.

XENON LASY AC-1015 1 301.90 lm

Luminaire Rectangulaire Encaissé Aire Lumineuse Rectangulaire Aire Lumineuse Horizontale Aire Lumineuse Plan 0° Aire Lumineuse Plan 90° Type de Symmétrie Distance de la mesure Operateur Température Humidité Notes Archives AGABEKOV 2008 C.I.E. F UTE 42 90 99 100 100 1.00 F

10 mm 0 mm 0.000000 m2 0.000000 m2 0.015017 m2 90 301.90 lm 230.00 V LMT

Aire Lumineuse Plan 180° Aire Lumineuse P lan 270° Aire Lumineuse à 76° Maximum Angle Gamma Flux de la mesure Tension d'alimentation Courant d'alimentation Cellule photo-électrique

ABDEL 25.00 ° C 60.00 % 17 XENON 10W 12V CL

Lampes Luminaire Réf. Nom XENON LASY AC-1015 XENON LASY AC-1015 D DIN 5040 B NBN A30 BZ 5 / 1.5 / BZ 4

Flux[lm] 301.90

Puis.[W] 170.0

Qté. 1

1015mm x 120mm 90 0 180 270 90 Demi-plans C 180.0 270.0 0.0 90.0 75 400 90 105 400 105 Angle Gamma 180 120

75

60

800

60

1200
ULOR DLOR RN 0.00 % 100.00 % 0.00 %

45 1600

45

2000 30 15 0 15

cd/klm 30

LITESTAR Open 10

(c)OxyTech Srl www.oxytech.it

www.agabekov.com

Dans la boutique



Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LESI 3W CL Name LESI-1025 IP65 17x12V3W CL Line AGABEKOV Efficiency 30.80% 417.24 cd/klm Length Length 0.090000 m2 0.000000 m2 0.000000 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-10I Name LESI-1025 IP65 17x12V5WCLEAR Date 12-03-2005 Coordinate system C-G Position 1025 mm 1000 mm Width Width 100 mm 90 mm Lamp Code Number Position Total Flux C=0.00 G=0.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LLNAL AB5000K Name LLNAL-1000 AB5000K Line AGABEKOV Efficiency Maximum value 75.21% 1997.90 cd/klm Length Length 0.033250 m2 0.000000 m2 0.000000 m2 Measurement Code LLNAL AB5000K Name Rail LOUVRE NEPTUNE LLN Date 01-00-0098 Coordinate system Position 980 mm 950 mm C-G C=0.00 G=0.00 Width Width 65 mm 35 mm Lamp Code Number Position Total Flux 1 510.00 lm Double Symmetrical Height Height 40 mm 0 0.000000 m2 0.000000 m2 0.008044 m2 90 510.00 lm 0.00 V 0.00 A Rectangular Luminaire...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Réf. ARL-AC 10W 24V Nom ARL-AC-0910 24V/10W FROSTED Archives AGABEKOV Rendement Valeur Maximum 100.00% 857.39 cd/klm Long. Long. 0.084165 m2 0.000000 m2 0.000000 m2 Asymétrique 0.00 OxyTech Mesure Réf. CLF1414/08-19I-BF Nom ARL-AC-0910 24V/10W FROSTED Date 25-02-2008 Syst. de Coordonnées C-G Position 910 mm 905 mm C=0.00 G=30.00 Larg. Larg. 120 mm 93 mm Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut. 15 909.00 lm Luminaire Rectangulaire Aire Lumineuse Rectangulaire...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LFX 3W CL Name LFX-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 75.73% 101.85 cd/klm Length Length 0.010000 m2 0.020000 m2 0.000200 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-09I Name LFX-1000 IP20 17X12V5WCLEAR Date 11-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 13 mm 10 mm Lamp Code Number Position Total Flux C=15.00 G=15.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU2X 3W CL Name LU2X-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 52.80% 169.64 cd/klm Length Length 0.035000 m2 0.020000 m2 0.000700 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-08I Name LU2X-1000IP20 17X12V5WCLEAR Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 38 mm 35 mm Lamp Code Number Position Total Flux C=195.00 G=5.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU3X 3W FR-RI Name LU3X-1000 IP20 17x12V3W FR-RI Line AGABEKOV Efficiency 31.75% 126.82 cd/klm Length Length 0.050000 m2 0.025000 m2 0.001250 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-06I Name LU3X-1000 IP20 17X12V8.5WFROST Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 52 mm 50 mm Lamp Code Number Position Total Flux C=285.00 G=15.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code ARLN T5-1510 80W NoGlass Name ARLN T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name ARLN T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU4AL BB2800K Name LU4AL-1000 BB2800K Line AGABEKOV Efficiency Maximum value 48.15% 176.20 cd/klm Length Length 0.025000 m2 0.000000 m2 0.000000 m2 Measurement Code LU4AL BB2800K Name Rail LU4AL-1000 Date 01-00-0098 Coordinate system Position 1000 mm 1000 mm C-G C=0.00 G=0.00 Width Width 25 mm 25 mm Lamp Code Number Position Total Flux 1 306.00 lm Double Symmetrical Height Height 20 mm 0 0.000000 m2 0.000000 m2 0.006048 m2 180 306.00 lm 0.00 V 0.00 A Rectangular Luminaire Rectangular...
 

035 0003 FEUX DE SIGNALISATION DIABOLO
035 0003 FEUX DE SIGNALISATION DIABOLO
22/02/2012 - www.loxam.fr
Ce modèle est présenté à titre indicatif comme un exemple de matériel référencé dans cette catégorie. Il ne présage pas du matériel proposé dans l agence que vous aurez sélectionnée. 2740 FEUX DE SIGNALISATION DIABOLO FEUX DE SIGNALISATION DIABOLO Code produit 035 0003 Optiques Ø 210 mm Hauteur mât maxi 2,74 m Tension 12 V Alimentation chargeur 230 V/12 V Batterie 12 V/200 Ah Autonomie 5 semaines Poids sans batteries 35 kg Document non contractuel www.loxam.fr ...

LIGHT SELLS  EN
LIGHT SELLS EN
12/09/2024 - www.regent.ch
LIGHT SELLS TRUE SWISS RETAIL CONTENTS Regent luminaires are designed and manufactured in accordance with EN standards and are subject to technical modification without prior notice. Regent assumes no liability for printing errors. 1st edition, February 2017. 4 FOCUS ON PRODUCTS 6 DIVERSITY OF LIGHT 8 SHOP WINDOWS 10 ENTRANCE AREAS 12 WALL AREAS / SHELVING 14 THE MAIN SPACE 16 AISLES AND HALLWAYS 18 SUPERMARKETS / SHELVED AREAS 22 FOOD, FISH, CHEESE, SPECIALS 24 SPECIAL OFFERS 26 ...

Rapport Annuel - Mecelec
Rapport Annuel - Mecelec
13/06/2016 - www.mecelec.fr
Rapport Annuel 2015 Société Anonyme au capital de 12.145.896 euros Siège Rapport Annuel 2015(Ardèche)  Page 1 sur 90 social Mauves 336 420 187 R.C.S AUBENAS INTRODUCTION ..................................................................................................................................... 3 Le mot du Président .............................................................................................................................................................. 4 Carte...

brochuremoduled318
brochuremoduled318
09/04/2011 - www.impact-even.com
MODULED 318 LUMINAIRE MODULAIRE À LEDS MODULED 318 est un luminaire modulaire à Leds équipé de 3 matrices de 18 Leds LUXEON haute puissance. Chaque matrice peut être contrôlée séparément et offre la possibilité de créer une palette infinie de couleurs riches et saturées. Les luminaires peuvent être utilisés individuellement ou couplés des rampes ou des panneaux. entre eux pour réaliser MODULED 318 a été conçu pour une utilisation en intérieur ou en extérieur. Le...


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF

Mise à la terre des camions-citernes Livre blanc - ADF SYSTÈMES
Mise à la terre des camions-citernes Livre blanc - ADF SYSTÈMES
06/12/2017 - www.adf-systemes.fr
Livre blanc Mise à la terre des camions-citernes Auteur: Mike O Brien, Responsable du marketing et des ventes chez Newson Gale. Question > Cliquez ici pour poser une question au sujet d'un produit ou demander un devis. Pour toute question sur les thèmes abordés dans cette étude de cas, vous pouvez directement contacter Mike à l adresse suivante : mike.obrien@hoerbiger.com Électricité statique et opérations de transfert de produit vers et depuis des camions-citernes. Les poudres et...