Photometrics data (PDF)

Extrait du fichier (au format texte) :

Luminaire Code LAFX 3W FR Name LAFX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 64.02% 210.89 cd/klm Length Length 0.025000 m2 0.025000 m2 0.000625 m2 Asymmetrical 8.70

Measurement Code CLF1414/05-17I Name LAFX-1000 IP20 17x12V 3W FROST Date 03-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 28 mm 25 mm

Lamp Code Number Position Total Flux C=240.00 G=5.00 Height Height

XENON 3W OP 12V 17 454.24 lm

Maximum value

Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° Symmetry Type Measurement Distance Operator Temperature Humidity Notes Line AGABEKOV C.I.E. F UTE 6 0.62 G + 0.02 T

27 mm 25 0.025000 m2 0.000625 m2 0.030305 m2 180 454.24 lm 230.00 V 0.00 A PRC 110

Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° Maximum Gamma Angle Measurement Flux Source Voltage Source Current Photocell

AC 25.00 °C 60.00 % XENON 12V 3W FROSTED Code XENON 3W OP 12V

Luminaire Lamps Name XENON RIGID LOOP LAMP 3W OP D DIN 5040 B NBN A31 BZ 5

Flux[lm] 26.72

Pow.[w] 3.0

Qta 17

1000mm x 28mm 90 Gamma Angle 180 120

180

0 105 50 105

270 90 C Halfplanes 180.0 90.0 0.0 270.0 75 50 75 90

100 60 60

150

ULOR DLOR

1.58 62.45 45 200 45

250 30 15 0 15

cd/klm 30

LITESTAR 7.S3

OxyTech Srl www.oxytech.it

Dans la boutique



Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LL3 3W FR Name LL3-1000 IP65 17x12V3W FR Line AGABEKOV Efficiency 51.68% 508.15 cd/klm Length Length 0.050000 m2 0.035000 m2 0.001750 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-02I Name LL3-1000 IP65 17X12V3WFROSTED Date 15-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 53 mm 50 mm Lamp Code Number Position Total Flux C=0.00 G=0.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code ARL T5-1510 80W No Glass Name ARL T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name ARL T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux Asymmetrical Height Height 1 6150.00 lm Rectangular Luminaire Rectangular Luminous Area...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU2X 3W CL Name LU2X-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 52.80% 169.64 cd/klm Length Length 0.035000 m2 0.020000 m2 0.000700 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-08I Name LU2X-1000IP20 17X12V5WCLEAR Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 38 mm 35 mm Lamp Code Number Position Total Flux C=195.00 G=5.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AMLN T5-1510 80W No Glass Name AMLN T5-1510 80W ASIM.WITH DF Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name AMLN T5-1510 80W ASIM.WITH DF Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux Asymmetrical Height Height 1 6150.00 lm Rectangular Luminaire Rectangular Luminous Area...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LFX 3W CL Name LFX-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 75.73% 101.85 cd/klm Length Length 0.010000 m2 0.020000 m2 0.000200 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-09I Name LFX-1000 IP20 17X12V5WCLEAR Date 11-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 13 mm 10 mm Lamp Code Number Position Total Flux C=15.00 G=15.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LRX 3W CL Name LRX-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 20.62% 135.39 cd/klm Length Length 0.039000 m2 0.033000 m2 0.001287 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-05I Name LRX-1000 IP20 17x12V 8.5W CLEA Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 41 mm 39 mm Lamp Code Number Position Total Flux C=105.00 G=5.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LECX 3W FR Name LECX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 31.79% 107.66 cd/klm Length Length 0.037000 m2 0.022000 m2 0.000814 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-07I Name LECX-1000 IP20 17X12V8.5WFROST Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 40 mm 37 mm Lamp Code Number Position Total Flux C=0.00 G=25.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code ARLN T5-1510 80W NoGlass Name ARLN T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name ARLN T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2...
 

035 0003 FEUX DE SIGNALISATION DIABOLO
035 0003 FEUX DE SIGNALISATION DIABOLO
22/02/2012 - www.loxam.fr
Ce modèle est présenté à titre indicatif comme un exemple de matériel référencé dans cette catégorie. Il ne présage pas du matériel proposé dans l agence que vous aurez sélectionnée. 2740 FEUX DE SIGNALISATION DIABOLO FEUX DE SIGNALISATION DIABOLO Code produit 035 0003 Optiques Ø 210 mm Hauteur mât maxi 2,74 m Tension 12 V Alimentation chargeur 230 V/12 V Batterie 12 V/200 Ah Autonomie 5 semaines Poids sans batteries 35 kg Document non contractuel www.loxam.fr ...

LIGHT SELLS  EN
LIGHT SELLS EN
12/09/2024 - www.regent.ch
LIGHT SELLS TRUE SWISS RETAIL CONTENTS Regent luminaires are designed and manufactured in accordance with EN standards and are subject to technical modification without prior notice. Regent assumes no liability for printing errors. 1st edition, February 2017. 4 FOCUS ON PRODUCTS 6 DIVERSITY OF LIGHT 8 SHOP WINDOWS 10 ENTRANCE AREAS 12 WALL AREAS / SHELVING 14 THE MAIN SPACE 16 AISLES AND HALLWAYS 18 SUPERMARKETS / SHELVED AREAS 22 FOOD, FISH, CHEESE, SPECIALS 24 SPECIAL OFFERS 26 ...

Rapport Annuel - Mecelec
Rapport Annuel - Mecelec
13/06/2016 - www.mecelec.fr
Rapport Annuel 2015 Société Anonyme au capital de 12.145.896 euros Siège Rapport Annuel 2015(Ardèche)  Page 1 sur 90 social Mauves 336 420 187 R.C.S AUBENAS INTRODUCTION ..................................................................................................................................... 3 Le mot du Président .............................................................................................................................................................. 4 Carte...

brochuremoduled318
brochuremoduled318
09/04/2011 - www.impact-even.com
MODULED 318 LUMINAIRE MODULAIRE À LEDS MODULED 318 est un luminaire modulaire à Leds équipé de 3 matrices de 18 Leds LUXEON haute puissance. Chaque matrice peut être contrôlée séparément et offre la possibilité de créer une palette infinie de couleurs riches et saturées. Les luminaires peuvent être utilisés individuellement ou couplés des rampes ou des panneaux. entre eux pour réaliser MODULED 318 a été conçu pour une utilisation en intérieur ou en extérieur. Le...


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF

Mise à la terre des camions-citernes Livre blanc - ADF SYSTÈMES
Mise à la terre des camions-citernes Livre blanc - ADF SYSTÈMES
06/12/2017 - www.adf-systemes.fr
Livre blanc Mise à la terre des camions-citernes Auteur: Mike O Brien, Responsable du marketing et des ventes chez Newson Gale. Question > Cliquez ici pour poser une question au sujet d'un produit ou demander un devis. Pour toute question sur les thèmes abordés dans cette étude de cas, vous pouvez directement contacter Mike à l adresse suivante : mike.obrien@hoerbiger.com Électricité statique et opérations de transfert de produit vers et depuis des camions-citernes. Les poudres et...