Photometrics data (PDF)

Extrait du fichier (au format texte) :

Luminaire Code LU3X 3W FR-RI Name LU3X-1000 IP20 17x12V3W FR-RI Line AGABEKOV Efficiency 31.75% 126.82 cd/klm Length Length 0.050000 m2 0.025000 m2 0.001250 m2 Asymmetrical 8.70

Measurement Code CLF1414/05-06I Name LU3X-1000 IP20 17X12V8.5WFROST Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 52 mm 50 mm

Lamp Code Number Position Total Flux C=285.00 G=15.00 Height Height

XENON 3W OP 12V 17 454.24 lm

Maximum value

Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° Symmetry Type Measurement Distance Operator Temperature Humidity Notes Line AGABEKOV C.I.E. F UTE 5/5/5/5/4/4/4/4/4/4/4/4 0.32 E + 0.00 T

28 mm 25 0.025000 m2 0.001250 m2 0.036353 m2 180 964.92 lm 230.00 V 0.00 A PRC 110

Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° Maximum Gamma Angle Measurement Flux Source Voltage Source Current Photocell

AC 25.00 °C 60.00 % 17x8.5W OPAL 12V XENON Code XENON 3W OP 12V

Luminaire Lamps Name XENON RIGID LOOP LAMP 3W OP D DIN 5040 B NBN A30 BZ 4

Flux[lm] 26.72

Pow.[w] 3.0

Qta 17

1000mm x 52mm 90 Gamma Angle 180 120

0 180 105 25 105

270 90 C Halfplanes 180.0 90.0 0.0 270.0 75 25 75 90

50 60 60

75

ULOR DLOR

0.01 31.73 45 100 45

125 30 15 0 15

cd/klm 30

LITESTAR 7.S3

OxyTech Srl www.oxytech.it

www.agabekov.com

Dans la boutique



Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code T5-0630-14W Name T5 FLUO IP 65 0630 14W Line AGABEKOV Efficiency Maximum value 53.48% 271.68 cd/klm Length Length 0.054180 m2 0.000000 m2 0.000000 m2 Measurement Code CLF1414/06-01I Name AGA-T5 Date 26-05-2006 Coordinate system Position 630 mm 630 mm C-G C=0.00 G=0.00 Width Width 549 mm 86 mm Lamp Code T5 14W Daylight 6500K° Number 1 Position Total Flux 1100.00 lm Sym. on planes 0-180 Height Height 65 mm 0 0.000000 m2 0.000000 m2 0.013107 m2 180 1200.00 lm 0.00 V 0.00 A Rectangular...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LAFX 3W FR Name LAFX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 64.02% 210.89 cd/klm Length Length 0.025000 m2 0.025000 m2 0.000625 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-17I Name LAFX-1000 IP20 17x12V 3W FROST Date 03-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 28 mm 25 mm Lamp Code Number Position Total Flux C=240.00 G=5.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AML T5-1510 80W No Glass Name AML T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name AML T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2 90...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LRX 3W CL Name LRX-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 20.62% 135.39 cd/klm Length Length 0.039000 m2 0.033000 m2 0.001287 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-05I Name LRX-1000 IP20 17x12V 8.5W CLEA Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 41 mm 39 mm Lamp Code Number Position Total Flux C=105.00 G=5.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LECX 3W FR Name LECX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 31.79% 107.66 cd/klm Length Length 0.037000 m2 0.022000 m2 0.000814 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-07I Name LECX-1000 IP20 17X12V8.5WFROST Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 40 mm 37 mm Lamp Code Number Position Total Flux C=0.00 G=25.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Réf. ARL-AC 10W 24V Nom ARL-AC-0910 24V/10W FROSTED Archives AGABEKOV Rendement Valeur Maximum 100.00% 857.39 cd/klm Long. Long. 0.084165 m2 0.000000 m2 0.000000 m2 Asymétrique 0.00 OxyTech Mesure Réf. CLF1414/08-19I-BF Nom ARL-AC-0910 24V/10W FROSTED Date 25-02-2008 Syst. de Coordonnées C-G Position 910 mm 905 mm C=0.00 G=30.00 Larg. Larg. 120 mm 93 mm Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut. 15 909.00 lm Luminaire Rectangulaire Aire Lumineuse Rectangulaire...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU2X 3W CL Name LU2X-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 52.80% 169.64 cd/klm Length Length 0.035000 m2 0.020000 m2 0.000700 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-08I Name LU2X-1000IP20 17X12V5WCLEAR Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 38 mm 35 mm Lamp Code Number Position Total Flux C=195.00 G=5.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Réf. LASY AL-1015 Nom LASY AL-1015 AGA-17LED Archives AGABEKOV 2008 Rendement Valeur Maximum 100.00% 2361.65 cd/klm Long. Long. 0.062075 m2 0.000000 m2 0.000000 m2 Asymétrique 6.47 Mesure Réf. CLF1414/08-21L Nom LASY AL-1015 AGA-17LED Date 04-09-2008 Syst. de Coordonn. Position 1015 mm 955 mm C-G C=345.00 G=21.00 Larg. Larg. 120 mm 65 mm Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut. LED LASY AL 1015 1 38.63 lm Luminaire Rectangulaire Encaissé Aire Lumineuse Rectangulaire...
 

Prévention des fissures de joints de prédalle : le choix du produit de traitement est crucial
Prévention des fissures de joints de prédalle : le choix du produit de traitement est crucial
29/09/2016 - www.andresudrie.com
Information Presse Septembre 2016 Avis d expert Prévention des fissures de joints de prédalle : le choix du produit de traitement est crucial Contrairement à une idée véhiculée dans la profession, la fissuration parfois observée sur les joints de prédalle, loin de relever d une cause structurelle, trouverait son origine dans leurs conditions de mise en oeuvre. Pour prévenir efficacement tout désordre, il s agit donc avant tout de choisir le produit adapté en fonction de la phase de...

Sanicubic® : des stations de relevage à poser simplement au sol pour des usages individuel, commercial ou collectif
Sanicubic® : des stations de relevage à poser simplement au sol pour des usages individuel, commercial ou collectif
24/06/2014 - www.n-schilling.com
COMMUNIQUÉ DE PRESSE en ligne sur www.n-schilling.com JUIN 2014 Sanicubic® : des stations de relevage à poser simplement au sol pour des usages individuel, commercial ou collectif. Les SANICUBIC® sont des stations de relevage à poser simplement au sol ! Plus besoin d enterrer les stations, d attendre de longues semaines de travaux pour voir enfin un produit installé mais enterré, donc compliqué à entretenir & Grâce aux SANICUBIC® de SFA, découvrez l inestimable gain de temps et...

Parts TWI UK
Parts TWI UK
19/06/2024 - aosmithinternational.com
Maintenance & Accessories Exploded view TWI II from 01-05-'19 20 19 1 11 13 A 3 12 15 A 14 16 10 9 24 6 18 5 4 17 2 8 21 7 22 REVIS COMP ON

Rfa Rougier 2020
Rfa Rougier 2020
25/06/2024 - www.rougier.fr
Rapport financier 2020 RAPPORT FINANCIER ANNUEL 2020 1. RAPPORT DE GESTION 3 2. COMPTES CONSOLIDES ANNUELS 33 3. COMPTES SOCIAUX ANNUELS 85 4. ASSEMBLEE GENERALE ORDINAIRE 113 Attestation des responsables du Rapport Financier Annuel 117 RAPPORT DE GESTION 1. PRESENTATION DE ROUGIER 4 1. 1. PROFIL DU GROUPE ET ORGANIGRAMME 4 1. 2. REPARTITION DU CAPITAL 5 1. 3. GOUVERNEMENT D'ENTREPRISE 5 1. 3. 1. ORGANES DE DIRECTION 5 1. 3 .2. ORGANES DE CONTROLE EXTERNE

14025 fr
14025 fr
09/04/2011 - www.tisserant.fr
Ref : 14025 H : 60 cm Ø : 66 cm Bras : 6 Lustre 'Mazarin' Bronze finition dorure 24 K

Isolation industrielle & HVAC : Knauf Insulation lance la 1ère génération de solutions pour l'isolation technique en laine minérale avec liant ECOSE® Technology
Isolation industrielle & HVAC : Knauf Insulation lance la 1ère génération de solutions pour l'isolation technique en laine minérale avec liant ECOSE® Technology
29/09/2016 - www.andresudrie.com
Information Presse Mars 2016 Isolation industrielle, chauffage, climatisation et ventilation Knauf Insulation lance la première génération de solutions pour l isolation technique en laine minérale avec liant ECOSE® Technology Avec plus de 30 ans d expérience, Knauf Insulation a révolutionné le marché de l isolation dans la construction en lançant, en 2009, la première laine minérale de verre avec liant ECOSE ® Technology, sans formaldéhyde, phénol, ni acrylique. Fort de ce succès...