BATTERY CHARGER
D.C POWER SUPPLY
CPN, HP, HPT series
A U T O M A T I S M E S
E N E R G I E
E L E C T R O N I Q U E
S Y S T E M E S
PRELIMINARY
AEES Company, specialist in emergency power supply for various applications provides a wide range of products. The charger rectifier is the common part of all these systems.
CHARGER
LOW RATING CHARGER for stationnary battery CE-CN.D-CPN.D/E-CMV Series 20039 leaflet UNINTERRUPTIBLE POWER ASD-ASC SERIES 20040 - 20050
LEAFLETS SUPPLY
RECTIFIER
DC FUNCTIONALITY
RELIABILITY PERFORMANCE STANDARD OR CUSTOM DESIGN
POWER SUPPLY
WITH BATTERY
IPP - ISP- ISPP - SPP Series 20043 - 20044 leaflets EMERGENCY LIGHTING EPP-ESP-PCC-SCC Series 20079 - 20080 leaflets DC
POWER SUPPLY
BATTERY
CHARGER UNIT
CPN-HP-HPT series : this 20046 leaflet is dedicated to them
REFERENCES
APPLICATIONS : Automatisms (relays, PLC...) Telephone exchanges (PABX) Switchboards for LV, MV, HV, Switchgears Emergency lighting Computers, data processings Alarm systems Machines (ticketing - tooling...) etc... USES : Transport (Subway, airport, railways...) Telecommunications Industry (oil, chemical, car...) Marine (Veritas, Lloyds...) Army Buildings (Sky scraper, commercial center...) O.E.M. Exportation (5 mainlands).
SYNOPTIQUE
INPUT MAINS
OUTPUT
EQUIPMENT
1 Overload and short circuit protection : Circuit breaker ......................................................................................................................... Fuse ........................................................................................................................................ 2 Pre-magnetization circuit (Rush of current limitation) ............................................................................. 3 Surge suppressor according to CEI 801.5. ............................................................................................. 4 Incoming circuit contactor ...................................................................................................................... 5 Input transformer ..................................................................................................................................... Regulated rectifier module including : 6 Diodes / thyristors bridge rectifier. ............................................................................................. 6 pulses rectifier bridge ............................................................................................................. «MCD» type rectifier bridge system providing same performances as a 12 pulses rectifier, but with higher reliability. As example (N version) : - Cos 0,92 - THD (current) 15%........................ 7 Electronic control unit. .............................................................................................................. 8 Smoothing unit : - Standard : LC type ................................................................................................................. - Improved : type .................................................................................................................. 9 Output voltage limitation : - Transistorized ballast .............................................................................................................. - Diodes dropper ...................................................................................................................... Overload and short circuit protection 10 Output circuit : fuse ......................................................................................................... Circuit breaker .......................................................................................... 11 Battery circuit : fuse isolator (Depending on configuration) ................................................. Circuit breaker .......................................................................................... 12 Battery temperature sensor for U = f () regulation ..................................................................................... 13 Line voltage drop compensation device (far away battery, high power supply...) ......................................... 14 Earth fault monitor (CPI) ............................................................................................................................ 15 Voltage monitoring of charger voltage ........................................................................................................ Voltage monitoring of battery voltage ......................................................................................................... Voltage monitoring of output voltage ......................................................................................................... 16 Charger switch-off when over battery voltage ............................................................................................ 17 Output switch-off when under battery voltage ........................................................................................... 18 « on-off » switch ........................................................................................................................................ 19 Remote control of the charger (for instance to enslave the charge operation, to the battery room ventilation) ..... 20 Switch or push button for manual charge control ......................................................................................... 21 Selector for Charge mode - Automatic mode - Manual mode ....................................................................... 22 Voltage selector for multi voltages system .................................................................................................... 23 Ajustable output voltage by potentiometer .................................................................................................. 24 Push button faults reset .............................................................................................................................. Signalling by L.E.D. or signal lamp (S) and free remote contact (R) : 25 A.C. healthy ............................................................ 26 Charge on .............................................................. 27 Charger fault .......................................................... 28 Charger voltage fault (overvoltage) ..................... 29 Battery voltage fault (undervoltage) .................... } 30 Earth fault ............................................................... 31 Manual charge on ................................................. Meters (72 x 72 - 90° scale) : 32 Charger flow ...................................................................................................................................................... 33 Output flow ........................................................................................................................................................ 34 Charge and discharge battery current ........................................................................................................... 35 Output voltage or battery voltage ................................................................................................................... 36 Input voltage ..................................................................................................................................................... 37 Digital indicator against moving coil indicator .................................................................................................................. 38 U and I measuring tansducers ........................................................................................................................................... 39 Man-machine communication-unit, maintenance aid, battery supervising, remote transmission ............................ 40 Interface (RS 232 - RS 485 - RS 422) ............................................................................................................................... 41 Automatic battery test device ............................................................................................................................................ 42 Additional outgoing feeders by circuit breakers ............................................................................................................... 43 Special make following specification ................................................................................................................................
CPN A B