BAC Retrofit PLC3 RetrofitOpportunities EN

Extrait du fichier (au format texte) :

RO_PLC3_EN_v00

PLC3

© 2024 Baltimore Aircoil International nv

Retrofit Opportunities

POLAIRIS CONDENSER

Improve maintenance and accessibility

Enhance operational safety

Reduce sound emission

Save water

External platform with ladder &
casing railing

Access door opposite end*

Additional intake & attenuation discharge
Intake
& discharge screens

Intake & discharge attenuation

Save energy and increase performance

Increase reliability

BCP automatic bleed control

Clean out port

* Only for 2,4m wide units
** Only for 1,2-1,4m wide units

Remote sump connection

Separator

Discharge hood

Heater package

Dans la boutique



BAC OriginalSpareParts SPARTv00EN
BAC OriginalSpareParts SPARTv00EN
18/08/2024 - www.baltimoreaircoil.be
Baltimore Aircoil BAC original spare parts ... ... keep your equipment fresh BAC original spare parts refresh your equipment to give you maximum confidence in the reliability of your cooling system. When you buy a BAC spare part you get more than just a component. You get a whole package of refreshing benefits that are only available from BAC : " Original performance for lowest system operating cost " Minimum downtime and maximum lifetime " Operational safety " Improved operation and maintenance...

BAC SPLC3 SPolairis V02 EN 0
BAC SPLC3 SPolairis V02 EN 0
18/08/2024 - www.baltimoreaircoil.be
Highest capacity condenser with the most reliable lifetime efficiency Evaporative Condenser, model PLC3 UNMATCHED RELIABILITY MAXIMUM UPTIME AND LONGEVITY Multiple, independent Fan Systems provide optimal reliability and guarantee redundancy. Baltibond® Hybrid Coating comes as standard for maximum equipment life, with corrosion resistance equivalent to SST 304L. Dry operation possible. ULTRA COMPACT Polairis!" Evaporative Condenser ENERGY EFFICIENT UP TO 50% SAVINGS COMPARED TO CONVENTIONAL...

BAC Parts PLC3 SpareParts EN
BAC Parts PLC3 SpareParts EN
18/08/2024 - www.baltimoreaircoil.be
PLC3 P PLC3 v01 EN © 2024 Baltimore Aircoil International nv 3 Polairis condenser 2 4 i i i i i i i 1. Drift eliminators 2. Spray branches 3. Spray branch grommets 4. Spray nozzles & nozzles grommets 5. Coil(s) 6. Upper pump piping 7. Sleeve & clamps 1 Spray pump with volute

BAC SService EN General V00
BAC SService EN General V00
18/08/2024 - www.baltimoreaircoil.be
The SERVICE EXPERT for BAC Equipment Tailored SERVICES and SOLUTIONS for your BAC cooling towers and equipment YOUR DEDICATED PARTNER IN INNOVATIVE HEAT TRANSFER AND THERMAL STORAGE ORIGINAL SPARE PARTS AND FILL FOR AN EFFICIENT, SAFE AND YEAR ROUND RELIABLE OPERATION We develop, design, test and manufacture most parts, fills and eliminators in house to ensure the highest quality and performance and safest operation. Rely on BAC's expertise to optimize your cooling equipment UPGRADES AND NEW...

BAC Retrofit PLC3 RetrofitOpportunities EN
BAC Retrofit PLC3 RetrofitOpportunities EN
18/08/2024 - www.baltimoreaircoil.be
RO_PLC3_EN_v00 PLC3 © 2024 Baltimore Aircoil International nv Retrofit Opportunities POLAIRIS CONDENSER Improve maintenance and accessibility Enhance operational safety Reduce sound emission Save water External platform with ladder & casing railing Access door opposite end* Additional intake & attenuation discharge Intake & discharge screens Intake & discharge attenuation Save energy and increase performance Increase reliability BCP automatic bleed control Clean out port * Only...

BAC Rigging PLC3 EN
BAC Rigging PLC3 EN
18/08/2024 - www.baltimoreaircoil.be
RPLC3-v00-EN PLC3 Evaporative Condensers RIGGING AND INSTALLATION INSTRUCTIONS About rigging and installation The BAC equipment should be rigged and installed as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the rigging and operation to acquaint all personnel with the procedures to be followed and to assure that all necessary equipment will be available at the job site. Be sure to have a copy of the unit certified drawing available for reference. If you do...

BAC Maintenance PLC3 EN
BAC Maintenance PLC3 EN
18/08/2024 - www.baltimoreaircoil.be
MPLC3-v00-EN PLC3 Evaporative Condensers OPERATING AND MAINTENANCE INSTRUCTIONS Recommended maintenance and monitoring programme Baltimore Aircoil Company equipment needs to be properly installed, operated and maintained. Documentation of the equipment used, including a drawing, technical data sheet and this manual should be kept on record. To achieve long, trouble-free and safe operation, it is necessary to establish an operating plan including a programme of regular inspection, monitoring...
 

eccocera-lait-tds-100531
eccocera-lait-tds-100531
09/04/2011 - www.terdici.com
Révision mai 2010 ECCOCERA ­ LAIT DE CIRE PRODUIT NATUREL Apporte brillance et protection aux enduits à la chaux Terdici Luigi Déco. Incolore ou aspect Nacre, Or ou Vieil Argent. EMULSION DE CIRES NATURELLES PRESENTATION Cires et huiles naturelles en émulsion pour une finition patinée et une protection des murs intérieurs. Existe en incolore, teinte nacrée, dorée ou argentée. Lustre et protège les décors à la chaux. CONDITIONS D'APPLICATION Température supérieure à 5°C et inférieure...

TESTO fait e'voluer la thermographie avec ses nouvelles came'ras thermiques intelligentes et connecte'es
testo 865s, testo 868s, testo 871s et testo 872s
TESTO fait e'voluer la thermographie avec ses nouvelles came'ras thermiques intelligentes et connecte'es testo 865s, testo 868s, testo 871s et testo 872s
16/05/2022 - www.andresudrie.com
Information Presse Mai 2022 TESTO fait evoluer la thermographie avec ses nouvelles cameras thermiques intelligentes et connectees testo 865s, testo 868s, testo 871s et testo 872s Beneficiant de plus de 60 ans d'expertise dans le domaine de la mesure, Testo est engage depuis toujours dans l'innovation pour offrir aux professionnels de tous les secteurs d'activites (batiment, industrie, &) des appareils de qualite, faciles a utiliser. Apres avoir lance en 2007 la premiere camera thermique entierement...


03/11/2024 - www.hoval.fr
Résumé en cours de création pour ce fichier PDF

Dpc8902 3 Prédalles Bp Rennes 12 2023
Dpc8902 3 Prédalles Bp Rennes 12 2023
02/07/2024 - www.kp1.fr
1164 08 1164-CPR-PRD008 DOCUMENT D'ACCOMPAGNEMENT ET DECLARATION DES PERFORMANCES N°8902-3 1.CODE D'IDENTIFICATION UNIQUE DU PRODUIT TYPE PREDALLE BETON PRECONTRAINT 2. NUMERO PERMETTANT L'IDENTIFICATION DU PRODUIT DE CONSTRUCTION 3. USAGE PREVU DU PRODUIT DE CONSTRUCTION, CONFORMEMENT A LA SPECIFICATION TECHNIQUE HARMONISEE APPLICABLE Prédalle en béton  Voir étiquette produit et dossier de conception 4. NOM, RAISON SOCIALE ET ADRESSE DE CONTACT DU FABRIQUANT Planchers à prédalles avec...

Nouvelle génération d'appareils de mesure compacts et connectés Testo pour le secteur CVC :
l'assurance d'un travail rapide, simple et précis
Nouvelle génération d'appareils de mesure compacts et connectés Testo pour le secteur CVC : l'assurance d'un travail rapide, simple et précis
13/02/2023 - www.andresudrie.com
Information Presse Fevrier 2023 Nouvelle generation d'appareils de mesure compacts et connectes Testo pour le secteur CVC l'assurance d'un travail rapide, simple et precis Que ce soit dans le cadre d'installation, d'entretien ou de maintenance, les professionnels du secteur du chauffage, de la ventilation et de la climatisation sont toujours en quete d'outils facilitant leur quotidien. Proche de leurs attentes, Testo fait evoluer sa gamme d'appareils de mesure pour le secteur CVC. Plus compacts,...

N 600664 Spilling
N 600664 Spilling
02/08/2024 - kvadrat-downloadcenter.azurewebsites.net
Doc. no. : SK-71 Page : 1 of 1 Revision no. : 9 Approved by : BV Test report Textile Pilling NS-EN ISO 12945-2 :2000 TEST 082 Client Product SAHCO GmbH KREUZBURGER STRASSE 17-19 DE-9047 1 NÜRNBERG Tyskland Art. MOSS Col. 21 Client's reference R-no. Nicole Frei R16567 Product specification  tested object Date Date of receipt, tested object Test completed date Rev. no. / Rev. date 24.06.2019 19.06.2019 21.06.2019