evaporative cooling

delivering the benefits of cooling towers and evaporative condensers

Protecting the environment with evaporative cooling
Minimum water usage

M

Minimum space

any processes, particularly in industrial applications, still use water for cooling purposes in a so-called once-through system .
The resulting thermal pollution and waste of this costly resource can be avoided with a system that recirculates the cooling water. The principle of evaporative cooling used in cooling towers and evaporative condensers saves over 95% of the recirculated water whilst providing other important environmental benefits.

ecause of its greater efficiency evaporative cooling equipment is more compact than air cooled alternatives and occupies less space.
Cooling towers or evaporative condensers can also be installed inside a building which is favoured by many architects. With space at a premium on most buildings and industrial sites evaporative cooling offers owners important space saving advantages.

Minimum energy consumption

Minimum noise

ir cooled equipment is often used to reject process heat,
particularly in air conditioning applications. However air cooled or
dry  systems are less efficient than evaporative cooled or wet  systems resulting in greater electrical energy consumption and they also have a higher first cost. The generation of electrical power is a major contributor to the greenhouse gas emissions which cause global warming. Evaporative cooling directly benefits the environment by minimising the use of electrical energy for cooling.

ooling towers and evaporative condensers are inherently quieter than air cooled alternatives as they require less airflow and hence fewer or smaller fans. In addition, because they achieve lower cooling temperatures, the associated refrigeration or process cooling plant can be smaller and thus quieter. As noise is increasingly of concern in our daily life the use of evaporative cooling

Dans la boutique



BAC CoolingTowerCertification PRD1403v01EN
BAC CoolingTowerCertification PRD1403v01EN
27/02/2025 - www.baltimoreaircoil.be
Cooling Tower Certification ...level competitive playground. WHAT DOES IT MEAN? TO THE INDUSTRY 99 Faster product development 99 Products with higher efficiency 99 CO2 footprint improvement TO YOU 99 Thermal performance assured 99 No field testing required 99 Value for money BAC participates in the ECC programme for cooling towers. Check ongoing validity of certificate: www.eurovent-certification.com INSIST ON Eurovent certified cooling towers EUROVENT cooling tower certification programme 99...

BAC General OpenCoolingTowers EN
BAC General OpenCoolingTowers EN
27/02/2025 - www.baltimoreaircoil.be
G BAC participates in the CTI-ECC programme for cooling towers Check ongoing validity of certificate: www. eurovent-certification.com A Best S1500E S3000E PTE VT0 / VT1 VTL-E Capacity 8 - 215 l/s 16 - 285 l/s 12- 170 l/s 7 - 455 l/s 3 - 130 l/s Configuration Crossflow Crossflow Counterflow Counterflow Counterflow Air entry Axial fan Induced draft Axial fan Induced draft

BAC OriginalSpareParts SPARTv00EN
BAC OriginalSpareParts SPARTv00EN
18/08/2024 - www.baltimoreaircoil.be
Baltimore Aircoil BAC original spare parts ... ... keep your equipment fresh BAC original spare parts refresh your equipment to give you maximum confidence in the reliability of your cooling system. When you buy a BAC spare part you get more than just a component. You get a whole package of refreshing benefits that are only available from BAC : " Original performance for lowest system operating cost " Minimum downtime and maximum lifetime " Operational safety " Improved operation and maintenance...

BAC SService EN General V00
BAC SService EN General V00
18/08/2024 - www.baltimoreaircoil.be
The SERVICE EXPERT for BAC Equipment Tailored SERVICES and SOLUTIONS for your BAC cooling towers and equipment YOUR DEDICATED PARTNER IN INNOVATIVE HEAT TRANSFER AND THERMAL STORAGE ORIGINAL SPARE PARTS AND FILL FOR AN EFFICIENT, SAFE AND YEAR ROUND RELIABLE OPERATION We develop, design, test and manufacture most parts, fills and eliminators in house to ensure the highest quality and performance and safest operation. Rely on BAC's expertise to optimize your cooling equipment UPGRADES AND NEW...

Eurovent CTI Article EN V01
Eurovent CTI Article EN V01
27/02/2025 - www.baltimoreaircoil.be
Eurovent Certita Certification (ECC) & Cooling Technology Institute (CTI) together provide industry certification of Cooling Towers and Closed Circuit Coolers covering the world. Performance certification is the basis for Endusers, consultants, Contractors, Manufacturers and Government to ensure correct investment in quality products. THE BASIC REQUIREMENT OF EVAPORATIVE COOLING EQUIPMENT & & Is rejecting the heat to the atmosphere of the process that needs to be cooled. At first sight an obvious...

BAC Parts PLC3 SpareParts EN
BAC Parts PLC3 SpareParts EN
18/08/2024 - www.baltimoreaircoil.be
PLC3 P PLC3 v01 EN © 2024 Baltimore Aircoil International nv 3 Polairis condenser 2 4 i i i i i i i 1. Drift eliminators 2. Spray branches 3. Spray branch grommets 4. Spray nozzles & nozzles grommets 5. Coil(s) 6. Upper pump piping 7. Sleeve & clamps 1 Spray pump with volute

BAC Maintenance PLC3 EN
BAC Maintenance PLC3 EN
18/08/2024 - www.baltimoreaircoil.be
MPLC3-v00-EN PLC3 Evaporative Condensers OPERATING AND MAINTENANCE INSTRUCTIONS Recommended maintenance and monitoring programme Baltimore Aircoil Company equipment needs to be properly installed, operated and maintained. Documentation of the equipment used, including a drawing, technical data sheet and this manual should be kept on record. To achieve long, trouble-free and safe operation, it is necessary to establish an operating plan including a programme of regular inspection, monitoring...

BAC Retrofit PLC3 RetrofitOpportunities EN
BAC Retrofit PLC3 RetrofitOpportunities EN
18/08/2024 - www.baltimoreaircoil.be
RO_PLC3_EN_v00 PLC3 © 2024 Baltimore Aircoil International nv Retrofit Opportunities POLAIRIS CONDENSER Improve maintenance and accessibility Enhance operational safety Reduce sound emission Save water External platform with ladder & casing railing Access door opposite end* Additional intake & attenuation discharge Intake & discharge screens Intake & discharge attenuation Save energy and increase performance Increase reliability BCP automatic bleed control Clean out port * Only...
 

CARACTÉRISTIQUES CERTIFIÉES Entrevous à base de ... - Seac
CARACTÉRISTIQUES CERTIFIÉES Entrevous à base de ... - Seac
21/02/2018 - www.seac-gf.fr
Entrevous à base de polystyrène expansé SEAC BOIS12 - SEAC BOIS15 - SEAC BOIS20 Le CSTB atteste que le produit ci-dessus est conforme à des caractéristiques décrites dans le référentiel de certification CSTBat 01, après évaluation selon les modalités de contrôle définies dans ce référentiel. Le CSTB accorde à la société Usine de SEAC GUIRAUD FRERES 47 Boulevard de Suisse F - 31021 TOULOUSE CEDEX 2 F - 31330 MERVILLE le droit d usage de la marque CSTBat Entrevous à base de...


15/10/2024 - www.dow.com
Résumé en cours de création pour ce fichier PDF


07/10/2024 - www.axeuro.com
Résumé en cours de création pour ce fichier PDF


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

Qu'il pleuve ou qu'il vente, on fait fi des caprices de la météo grâce aux vérandas Kajole
Qu'il pleuve ou qu'il vente, on fait fi des caprices de la météo grâce aux vérandas Kajole
23/05/2013 - www.andresudrie.com
MONTPELLIER Z.I. - Rue de la Garenne 34748 Vendargues cedex Tél. : 04 67 87 77 77 Fax : 04 67 87 77 00 www.kawneer-france.com Information Presse Mai 2013 Vérandas KAJOLE Des espaces uniques d élégance et de confort pour toute l année Manger, lire, faire de l exercice, prendre un bain ou tout simplement rêver en contemplant le coucher du soleil ou les étoiles est un privilège. Pour pouvoir profiter de ces plaisirs tous les mois de l année sans se préoccuper des caprices de la météo,...

4 Chaufferies OSICA Aubervilliers
4 Chaufferies OSICA Aubervilliers
01/07/2024 - www.tigr.fr
Référence Logement neuf Localisation : Aubervilliers (92) Application : Production calorifique et ECS Maitre d'ouvrage : OSICA Année de livraison : 2014 Composition de la solution : Quatre chaufferies préfabriquées en terrasse Carrosserie en ALUMINIUM M0 GENERATEUR CHAUFFAGE : Chaufferie A/B 230kW 2 chaudières Condensagaz + 1 ballon ECS de 750L + 1 ballon solaire 1000L + 1 ballon solaire 1500L Chaufferie D/E/H 460kW 2 chaudières Condensagaz + 1 ballon ECS de 1000L + 2 ballons solaires...