Technische Daten Spannung 230 V Schutzklasse II Zulässige Betriebstemperatur -70 ° bis 200 ° C C Typ Model Type Länge beheizt Heated length Longueur chauffante Leistung Wattage Puissance Bestimmungsgemäße Verwendung Tauwasserablaufheizung Tropfwannenheizung 40 W/m
Technical data Electric tension 230 V Protection class II Admissible operating temperature -70 ° to 200 ° C C
Caractéristiques techniques Tension 230 V Classe de protection II Température de service admissible de -70 ° à 200 ° C C
BS040F0100AAA
BS040F0200AAA
BS040F0300AAA
BS040F0400AAA
BS040F0500AAA
BS040F0600AAA
1m 40 W
2m 80 W
3m 120 W
4m 160 W
5m 200 W
6m 240 W
Determined use Heating of drain pipe Heating of drip pan
Précautions d'utilisation Chauffage pour tuyauterie d'écoulement. Chauffage pour bac de condensat. Le montage et le branchement doivent s'effectuer conformément aux instructions d'installation. Toute utilisation ne respectant pas les précautions d'utilisation est interdite.
Montage und Anschluss müssen nach dieser Anleitung erfolgen. Alle nicht bestimmungsgemäßen Verwendungen sind verboten.
Mounting and connection must be carried out according to these instructions. Use for applications other than listed above is not allowed.
Sicherheitsvorschriften Bei der Montage und Inbetriebnahme sind alle Sicherheits- und Unfallverhütungs-vorschriften sowie die Richtlinien und Normen im Einbauland zu beachten. Das Heizkabel darf nur von einer autorisierten Fachkraft montiert werden! Der Elektroanschluss darf nur von einer Elektrofachkraft gemäß den elektrotechnischen Regeln vorgenommen werden. Veränderungen am Heizkabel sind nicht zulässig. Montage Das Heizkabel darf nicht gekürzt werden. Das Heizkabel nicht befestigen, z.B. mit Schellen. Das Heizkabel darf nicht mit scharfen Kanten in Berührung kommen. Das Heizkabel darf sich an keiner Stelle überkreuzen oder berühren. Min. Biegeradius 25 mm Das Heizkabel ist so zu verlegen, dass es zu keinem Wärmestau kommt. Das Heizkabel darf nicht über oder durch brennbare Materialien geführt werden. Elektrische Absicherung und Schutzmaßnahmen sind bauseits vorzunehmen. Vor Inbetriebnahme ist eine Isolationsprüfung vorzunehmen. Bei Verlegung in Metallrohren sind diese in die Schutzmaßnahmen einzubeziehen (Erdung der Rohre). Technische Änderungen vorbehalten.
Safety regulations For mounting and start up all regulations for safety and accident prevention as well as directions and standards of the individual country have to be observed. The heating cable may only be mounted by authorized personell! The electrical connection may only be made by an electrical technician according to the electrotechnical regulations. Modifications on the heating cable are not allowed. Mounting The heating cable or cold lead must not be shortened. Do not fix the heating cable, e.g. with clamps. The heating cable must not touch any sharp edged parts. The heating cable must not cross or touch itself at any place. Min. bending radius 25 mm The heating cable must be mounted in a way that avoids accumulation of heat. The heating cable must not be put across or through combustible material. Electrical security and and safety measures are to be provided on site. Perform insulation test before start-up. If used in metal pipes, they have to be included in the electrical safety measures (pipes to be earthed). Subject to technical changes.
Consignes de sécurité Le montage et la mise en service sont soumis aux normes, consignes de sécurité et prescriptions de prévention des accidents en vigueur du pays. L'installation devra être réalisée par des professionnels reconnus! Les raccordements électriques doivent être effectués par des professionnels conformément aux normes en vigueur dans le pays. Les modifications du câble chauffant sont interdites. Installation Ne pas couper la partie chauffante ou le câble d'alimentation. Ne pas fixer le câble chauffant (par exemple : colliers de serrage). Le câble chauffant ne doit pas être en contact avec des pièces de forme angulaire et/ou tranchantes. Le câble chauffant ne doit pas se chevaucher ou s'entrecroiser. Rayon de courbure mini : 25 mm. Le montage du câble chauffant doit permettre d'éviter toute accumulation de chaleur. Le câble chauffant ne doit pas traverser et/ou être en contact avec des matériaux combustibles. Les systèmes de protection électrique (fusibles, disjoncteurs,...) doivent être prévus sur site. Effectuer des mesures d'isolement électrique avant la mise en fonctionnement. En cas d'utilisation à l'intérieur de tuyauteries métalliques il faut s'assurer du respect des normes de sécurité (mise à la terre des tuyauteries). Ce document peut être modifié sans préavis.
DOC0528A