En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534

Extrait du fichier (au format texte) :

1 SMOKE AND HEAT EXHAUST HOUSING

Smoke exhaust dampers and air inlets

11057534

ParkONE car park unit DAH HS 16-20A LS 4-6A
The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust.

ParkONE car park smoke and heat exhaust system unit for multi-

PRODUCT BENEFITS

" Programmable timer to meet ventilation needs while saving energy
" 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort

Product description
Thanks to its built-in clock, the residential car park smoke and heat exhaust system can program the fan (Off/Smoke and heat exhaust/Comfort) in anticipation of vehicle traffic in the car park. This system is especially suited to parking areas for multi-occupancy residential buildings. It controls the activation of manual smoke and heat exhaust and shutdown of smoke exhaust when instructed by the Fire service.

Fields of application
Multi-occupancy residential housing, New, Refurbishment, Non-residential buildings

Installation
" Smoke and heat exhaust unit attached to wall.

Reference arguments
" IP55 key-operated plastic box.
" Dimensions: length x width x depth = 375 x 375 x 200 mm.
" Backed-up weekly programmable timer.
" Motor protected at high and low speed by thermal-magnetic circuit breakers. Current intensity selected according to motors used.
" Range for 2-speed motor with Dahlander windings. 3-phase 400 V
" Input/output terminals for manual smoke control trip devices, current break (opening dry contact).
" Possible to connect key-operated fire brigade shut-off (opening dry contact).
" Manual and plans available from your local branch.

Main characteristics
" IP55 key-operated plastic box,
" dimensions for models 4 to 32A: lxhxd= 375 x 375 x 180 mm,
" dimensions for models 40 to 57A: lxhxd= 375 x 500 x 230 mm,
" dimensions for 2 fan models : lxhxd= 375 x 750 x 230 mm,
" backed-up weekly programmable timer,
" motor protected at high and low speed with thermal-magnetic circuit breakers,
current intensity selected according to motors used,
" range for 2-speed motor with Dahlander windings, 3-phase 400V
" input/output terminals for manual triggering devices current break (opening dry contact)

Dans la boutique



En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057538 ParkONE car park unit DAH HS 50-58A LS 16-24A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057537 ParkONE car park unit DAH HS 32-40A LS 12-16A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Dah 2 Fans 11057539
En Export Aldes Parkone Car Park Dah 2 Fans 11057539
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057539 ParkONE CAR PARK DAH 2 FANS The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort Product...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057529 ParkONE car park unit DAH HS 2.5-4 A LS 1-1.6 A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust unit PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort Product...

En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057535 ParkONE car park unit DAH HS 20-25A LS 9-12A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057530 ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057536 ParkONE car park unit DAH HS 25-32A LS 6-10A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Manual Trip Device 11044121
En Export Aldes Manual Trip Device 11044121
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11044121 Manual trip device The manual trip device is used in a smoke and heat exhaust system in multi-occupancy housing. Manual trip device PRODUCT BENEFITS " compliance: NF-S 61936, " easily identified red box, " simple and fast to install. Principles of operation The manual activation device is used to report the outbreak of a fire. Once activated manually, it reports the information to the smoke exhaust control...
 


05/03/2025 - www.fundermax.at
Résumé en cours de création pour ce fichier PDF

EvaluationOfNewWoodenPoles
EvaluationOfNewWoodenPoles
09/04/2011 - www.cbs-cbt.com
NON-DESTRUCTIVE EVALUATION FOR NEW WOODEN POLES QUALITY ASSESSMENT Authors: Jean-Luc Sandoz, Dr. Ing. Yann Benoit, Dr. Ing. PROVISORY VERSION INTRODUCTION The selection of wood poles used as supports for telecom or power overhead lines is visually operated. National or companies standards define the wood poles mechanical classes based, for each species, on some material singularities (knots, slope of grain, annual rings...) and intrinsic properties (length, diameter, weight...). If this visual...

Jasmine SEB39CC
Jasmine SEB39CC
16/02/2025 - www.farrow-ball.com
PRODUKTANVISNINGSBLAD JASMINE WALLPAPER - 39 Alla Farrow & Ball -tapeter ?r tillverkade av milj?v?nligt papper och v?r egen vattenbaserade f?rg med l?g VOC-halt. Pappersinformation: Det h?r tropiskt inspirerade m?nstret som f?rest?ller en v?ldoftande frodig v?xt fr?n ett varmare klimat kommer fr?n Farrow & Ball s arkiv och har moderniserats med nya f?rgkombinationer. M?nsternummer: Bok: F?reg?ende bok: BP39 Latest and Greatest N/A M?nsterrapport/Randbredd: Full rullbredd: Rull?ngd: 37.5cm...


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF

menuiseries pvc - AMCC
menuiseries pvc - AMCC
07/06/2017 - www.amcc-fenetres.fr
MENUISERIES PVC Décision d'admission n° 1165-06-43 du 16 novembre 1996 Décision de reconduction n° 3061A-06-43 du 24 juillet 2008 Cette décision annule et remplace la décision n°2890A-06-43 du 24 janvier 2007 La société AMCC FENÊTRES ET PORTES 9, 11 RUE DU RONDEAU  BP185 FR-36004 CHATEAUROUX Usine de FR-36004 CHATEAUROUX est autorisée à apposer les marques NF, CSTBat et ACOTHERM en application des règles générales des marques NF, CSTBat, des règles de certification NF220 /...