En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533

Extrait du fichier (au format texte) :

1 SMOKE AND HEAT EXHAUST HOUSING

Smoke exhaust dampers and air inlets

11057533

ParkONE car park unit DAH HS 10-16A LS 4-6A
The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust.

ParkONE car park smoke and heat exhaust system unit for multi-

PRODUCT BENEFITS

" Programmable timer to meet ventilation needs while saving energy
" 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort

Product description
Thanks to its built-in clock, the residential car park smoke and heat exhaust system can program the fan (Off/Smoke and heat exhaust/Comfort) in anticipation of vehicle traffic in the car park. This system is especially suited to parking areas for multi-occupancy residential buildings. It controls the activation of manual smoke and heat exhaust and shutdown of smoke exhaust when instructed by the Fire service.

Fields of application
Multi-occupancy residential housing, New, Refurbishment, Non-residential buildings

Installation
" Smoke and heat exhaust unit attached to wall.

Reference arguments
" IP55 key-operated plastic box.
" Dimensions: length x width x depth = 375 x 375 x 200 mm.
" Backed-up weekly programmable timer.
" Motor protected at high and low speed by thermal-magnetic circuit breakers. Current intensity selected according to motors used.
" Range for 2-speed motor with Dahlander windings. 3-phase 400 V
" Input/output terminals for manual smoke control trip devices, current break (opening dry contact).
" Possible to connect key-operated fire brigade shut-off (opening dry contact).
" Manual and plans available from your local branch.

Main characteristics
" IP55 key-operated plastic box,
" dimensions for models 4 to 32A: lxhxd= 375 x 375 x 180 mm,
" dimensions for models 40 to 57A: lxhxd= 375 x 500 x 230 mm,
" dimensions for 2 fan models : lxhxd= 375 x 750 x 230 mm,
" backed-up weekly programmable timer,
" motor protected at high and low speed with thermal-magnetic circuit breakers,
current intensity selected according to motors used,
" range for 2-speed motor with Dahlander windings, 3-phase 400V
" input/output terminals for manual triggering devices current break (opening dry contact)

Dans la boutique



En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057529 ParkONE car park unit DAH HS 2.5-4 A LS 1-1.6 A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust unit PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort Product...

En Export Aldes Manual Trip Device 11044121
En Export Aldes Manual Trip Device 11044121
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11044121 Manual trip device The manual trip device is used in a smoke and heat exhaust system in multi-occupancy housing. Manual trip device PRODUCT BENEFITS " compliance: NF-S 61936, " easily identified red box, " simple and fast to install. Principles of operation The manual activation device is used to report the outbreak of a fire. Once activated manually, it reports the information to the smoke exhaust control...

En Export Aldes Parkone Car Park Unit Dah Hs 4 6 3a Ls 1 6 2 4a 11057531
En Export Aldes Parkone Car Park Unit Dah Hs 4 6 3a Ls 1 6 2 4a 11057531
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057531 ParkONE car park unit DAH HS 4-6.3A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057536 ParkONE car park unit DAH HS 25-32A LS 6-10A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057537 ParkONE car park unit DAH HS 32-40A LS 12-16A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057530 ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057534 ParkONE car park unit DAH HS 16-20A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057533 ParkONE car park unit DAH HS 10-16A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...
 


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

kV - Nexans
kV - Nexans
30/06/2016 - www.nexans.com
DÉRIVATION UNIPOLAIRE MIXTE RUBANÉE Type DURM-PS pour tension maximale de 12/20 (24) kV Utilisation S Câble principal : - unipolaire à champ radial au papier imprégné NF C 33-100. S Câble dérivé : - Câble unipolaire à isolant synthétique NF C 33-223 (HN 33-S-23) ou NF C 33-220 (HN 33-S-22) S Section : - de 1 x 50 mm2 à 1 x 240 mm2 Installation Chaque conditionnement contient le nécessaire pour réaliser une dérivation unipolaire mixte rubanée, ainsi qu une notice de montage détaillée. Le...

Fr Brochure Rockfon Mono Acoustic 2024
Fr Brochure Rockfon Mono Acoustic 2024
09/07/2024 - www.rockfon.fr
2 ÉLÉGANCE ARCHITECTURALE ET ACOUSTIQUE. Créez un look unique et une acoustique excellente en un seul chef-d'Suvre. Rockfon Mono Acoustic offre des possibilités illimitées pour concevoir des plafonds et des murs architecturaux expressifs dans n'importe quelle couleur ou forme. Qu'ils soient plats, inclinés ou courbés, vous êtes entièrement libre d'innover. Fabriqué à partir de laine de roche recyclable, Rockfon Mono Acoustic reflète les tendances actuelles en matière de design...

uk223d
uk223d
09/04/2011 - www.desbordes.com
Technical data sheet Type 223D 03 System EB anti-pollution non-return valve Applications and special features · Operates in any position · Minimum head loss · Particularly suitable for pressure water · Does not generate hammering · Closing system : axial guiding with · Excellent sealing at high as well as at low · Drilled bosses 1/4" brass plug · Incrustation resistant materials systems. return spring pressure. Technical description DN " 1/2 3/4 1 1 1/4 1 1/2 2 PFA (bar) 16 16 16...


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF


02/12/2024 - www.sia-abrasives.com
Résumé en cours de création pour ce fichier PDF