1 SMOKE AND HEAT EXHAUST HOUSING

Smoke exhaust dampers and air inlets

11057533

ParkONE car park unit DAH HS 10-16A LS 4-6A
The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust.

ParkONE car park smoke and heat exhaust system unit for multi-

PRODUCT BENEFITS

" Programmable timer to meet ventilation needs while saving energy
" 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort

Product description
Thanks to its built-in clock, the residential car park smoke and heat exhaust system can program the fan (Off/Smoke and heat exhaust/Comfort) in anticipation of vehicle traffic in the car park. This system is especially suited to parking areas for multi-occupancy residential buildings. It controls the activation of manual smoke and heat exhaust and shutdown of smoke exhaust when instructed by the Fire service.

Fields of application
Multi-occupancy residential housing, New, Refurbishment, Non-residential buildings

Installation
" Smoke and heat exhaust unit attached to wall.

Reference arguments
" IP55 key-operated plastic box.
" Dimensions: length x width x depth = 375 x 375 x 200 mm.
" Backed-up weekly programmable timer.
" Motor protected at high and low speed by thermal-magnetic circuit breakers. Current intensity selected according to motors used.
" Range for 2-speed motor with Dahlander windings. 3-phase 400 V
" Input/output terminals for manual smoke control trip devices, current break (opening dry contact).
" Possible to connect key-operated fire brigade shut-off (opening dry contact).
" Manual and plans available from your local branch.

Main characteristics
" IP55 key-operated plastic box,
" dimensions for models 4 to 32A: lxhxd= 375 x 375 x 180 mm,
" dimensions for models 40 to 57A: lxhxd= 375 x 500 x 230 mm,
" dimensions for 2 fan models : lxhxd= 375 x 750 x 230 mm,
" backed-up weekly programmable timer,
" motor protected at high and low speed with thermal-magnetic circuit breakers,
current intensity selected according to motors used,
" range for 2-speed motor with Dahlander windings, 3-phase 400V
" input/output terminals for manual triggering devices current break (opening dry contact)

Dans la boutique



En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057533 ParkONE car park unit DAH HS 10-16A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057529 ParkONE car park unit DAH HS 2.5-4 A LS 1-1.6 A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust unit PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort Product...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057530 ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057534 ParkONE car park unit DAH HS 16-20A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057535 ParkONE car park unit DAH HS 20-25A LS 9-12A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057538 ParkONE car park unit DAH HS 50-58A LS 16-24A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
En Export Aldes Parkone Car Park Unit Dah Hs 32 40a Ls 12 16a 11057537
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057537 ParkONE car park unit DAH HS 32-40A LS 12-16A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057532 ParkONE car park unit DAH HS 6.3-10A LS 2.4-4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...
 

A06 3 4 69 Elm Galis Condens Fiche Qce 230418
A06 3 4 69 Elm Galis Condens Fiche Qce 230418
09/08/2024 - www.elmleblanc.fr
MARQUE elm.leblanc Date 28/03/2023 Version 1.0 Référence du produit 7738100332 Code EAN 4054925274462 Gamme égalis CONDENS Modèle GVS C 35-1M Qualités et caractéristiques environnementales du produit Incorporation de matières recyclées Recyclabilité Produit majoritairement recyclable Métaux précieux Contient au moins 1 milligramme de métaux précieux Terres rares Contient au moins 1 milligramme de terres rares - 4,4'-isopropylidènediphénol - Acide silicique, sel de plomb - Décaméthylcyclopentasiloxane -...

Notice De Pose Accord Droit
Notice De Pose Accord Droit
02/07/2024 - www.gimm.fr
Poutre Centrale Droit Exemple d'escalier 13 marches droit - rampe à droite. CALES FOURNIES Plaquette arrivée. 2 platines de réglage épaisseur 6 mm. 12) M (x M P A Q S R 1 01746 - NOTICE ESCALIER DROIT 13M STUDIO - 201710 Gabarit 11 12 1 2 10 9 3 8 4 7 6 1


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF


01/03/2025 - www.malerba.fr
Résumé en cours de création pour ce fichier PDF

Document Technique d?Application Paracier FM, revêtement d?étanchéité bicouche à base de feuilles en bitume modifié par SBS
Document Technique d?Application Paracier FM, revêtement d?étanchéité bicouche à base de feuilles en bitume modifié par SBS
28/06/2013 - www.siplast.fr
Document Technique d Application Référence Avis Technique 5/11-2225 Annule et remplace l Avis Technique 5/02-1581 avec modificatifs *01 Mod à *07 Mod Revêtement d étanchéité bicouche à base de feuilles en bitume modifié par SBS Revêtement d étanchéité de toiture Roof waterproofing system Paracier FM Dachabdichtung    objet de l Agrément Technique Européen     Titulaire : Icopal SAS 12 rue de la Renaissance FR-92184 Antony Cedex Usines : Mondoubleau (Loir et Cher) Loriol...

CHANNEL S UP FOLDER   V3  DE
CHANNEL S UP FOLDER V3 DE
12/09/2024 - www.regent.ch
DREI OPTIKEN. FÜR JEDEN ANSPRUCH DAS RICHTIGE LICHT. DIE NEUE CHANNEL S UP IST DIE VIEL SCHLANKERE VERSION DER BEWÄHRTEN UND BELIEBTEN LICHTLINIE CHANNEL UND BIETET NUN ZUSÄTZLICHES INDIREKTES LICHT. ALS PENDEL­LEUCHTE SOWIE LICHTKANALSYSTEM ERHÄLTLICH INTEGRIERT SIE SICH ELEGANT IN DIE ARCHITEKTUR UND ÜBERZEUGT DURCH HOHE ENERGIEEFFIZIENZ. KOMPROMISSLOS ERFÜLLT SIE DABEI ALLE NORMVORGABEN FÜR DIE ARBEITSPLATZBELEUCHTUNG. CHANNEL S UP C-LED SORTIMENT CHANNEL S UP PENDELLEUCHTE KOMPLETT...