1 SMOKE AND HEAT EXHAUST HOUSING

Smoke exhaust dampers and air inlets

11057531

ParkONE car park unit DAH HS 4-6.3A LS 1.6-2.4A
The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust.

ParkONE car park smoke and heat exhaust system unit for multi-

PRODUCT BENEFITS

" Programmable timer to meet ventilation needs while saving energy
" 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort

Product description
Thanks to its built-in clock, the residential car park smoke and heat exhaust system can program the fan (Off/Smoke and heat exhaust/Comfort) in anticipation of vehicle traffic in the car park. This system is especially suited to parking areas for multi-occupancy residential buildings. It controls the activation of manual smoke and heat exhaust and shutdown of smoke exhaust when instructed by the Fire service.

Fields of application
Multi-occupancy residential housing, New, Refurbishment, Non-residential buildings

Installation
" Smoke and heat exhaust unit attached to wall.

Reference arguments
" IP55 key-operated plastic box.
" Dimensions: length x width x depth = 375 x 375 x 200 mm.
" Backed-up weekly programmable timer.
" Motor protected at high and low speed by thermal-magnetic circuit breakers. Current intensity selected according to motors used.
" Range for 2-speed motor with Dahlander windings. 3-phase 400 V
" Input/output terminals for manual smoke control trip devices, current break (opening dry contact).
" Possible to connect key-operated fire brigade shut-off (opening dry contact).
" Manual and plans available from your local branch.

Main characteristics
" IP55 key-operated plastic box,
" dimensions for models 4 to 32A: lxhxd= 375 x 375 x 180 mm,
" dimensions for models 40 to 57A: lxhxd= 375 x 500 x 230 mm,
" dimensions for 2 fan models : lxhxd= 375 x 750 x 230 mm,
" backed-up weekly programmable timer,
" motor protected at high and low speed with thermal-magnetic circuit breakers,
current intensity selected according to motors used,
" range for 2-speed motor with Dahlander windings, 3-phase 400V
" input/output terminals for manual triggering devices current break (opening dry contact)

Dans la boutique



En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057538 ParkONE car park unit DAH HS 50-58A LS 16-24A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057535 ParkONE car park unit DAH HS 20-25A LS 9-12A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Manual Trip Device 11044121
En Export Aldes Manual Trip Device 11044121
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11044121 Manual trip device The manual trip device is used in a smoke and heat exhaust system in multi-occupancy housing. Manual trip device PRODUCT BENEFITS " compliance: NF-S 61936, " easily identified red box, " simple and fast to install. Principles of operation The manual activation device is used to report the outbreak of a fire. Once activated manually, it reports the information to the smoke exhaust control...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057530 ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
En Export Aldes Parkone Car Park Unit Dah Hs 25 32a Ls 6 10a 11057536
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057536 ParkONE car park unit DAH HS 25-32A LS 6-10A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
En Export Aldes Parkone Car Park Unit Dah Hs 10 16a Ls 4 6a 11057533
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057533 ParkONE car park unit DAH HS 10-16A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057534 ParkONE car park unit DAH HS 16-20A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057532 ParkONE car park unit DAH HS 6.3-10A LS 2.4-4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...
 


13/03/2025 - www.legrand.fr
Résumé en cours de création pour ce fichier PDF


01/03/2025 - www.malerba.fr
Résumé en cours de création pour ce fichier PDF


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

2017 11 07 Pr Nexans Q3 2017
2017 11 07 Pr Nexans Q3 2017
19/08/2024 - www.nexans.com
PRESS RELEASE 2017 THIRD-QUARTER FINANCIAL INFORMATION ð· Organic sales growth1 of 6.7%2 for the third quarter, led by submarine high-voltage operations; stable sales for non-project-related business (up 0.6% year on year) ð· Upturn in business in Europe and the Middle East/Africa region, offsetting weakness in America and for Oil & Gas sector activities ð· Growth for sales of cables to telecommunications operators (up 7.2%) but negative trends for LAN cables and systems (sales down 8.8%) Paris,...


24/03/2025 - www.dow.com
Résumé en cours de création pour ce fichier PDF

VFB - Joventa
VFB - Joventa
20/04/2017 - www.joventa.fr
V F B - VA N N E S PA P I L L O N SERVOMOTEURS ET VANNES Série VFB - Vannes papillons Motorisées Les vannes papillon de la série VFB sont conçues pour sécuriser ou réguler le débit d eau chaude, d eau froide ou de solutions glycolées, en fonction du signal de commande d un régulateur dans les applications de Chauffage, Ventilation et de Conditionnement d air. Elles sont testées pour garantir une étanchéité à 100% dans les deux sens, jusqu à leur pression de fermeture maximum. Disponibles...