1 SMOKE AND HEAT EXHAUST HOUSING

Smoke exhaust dampers and air inlets

11057530

ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A
The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust.

ParkONE car park smoke and heat exhaust system unit for multi-

PRODUCT BENEFITS

" Programmable timer to meet ventilation needs while saving energy
" 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort

Product description
Thanks to its built-in clock, the residential car park smoke and heat exhaust system can program the fan (Off/Smoke and heat exhaust/Comfort) in anticipation of vehicle traffic in the car park. This system is especially suited to parking areas for multi-occupancy residential buildings. It controls the activation of manual smoke and heat exhaust and shutdown of smoke exhaust when instructed by the Fire service.

Fields of application
Multi-occupancy residential housing, New, Refurbishment, Non-residential buildings

Installation
" Smoke and heat exhaust unit attached to wall.

Reference arguments
" IP55 key-operated plastic box.
" Dimensions: length x width x depth = 375 x 375 x 200 mm.
" Backed-up weekly programmable timer.
" Motor protected at high and low speed by thermal-magnetic circuit breakers. Current intensity selected according to motors used.
" Range for 2-speed motor with Dahlander windings. 3-phase 400 V
" Input/output terminals for manual smoke control trip devices, current break (opening dry contact).
" Possible to connect key-operated fire brigade shut-off (opening dry contact).
" Manual and plans available from your local branch.

Main characteristics
" IP55 key-operated plastic box,
" dimensions for models 4 to 32A: lxhxd= 375 x 375 x 180 mm,
" dimensions for models 40 to 57A: lxhxd= 375 x 500 x 230 mm,
" dimensions for 2 fan models : lxhxd= 375 x 750 x 230 mm,
" backed-up weekly programmable timer,
" motor protected at high and low speed with thermal-magnetic circuit breakers,
current intensity selected according to motors used,
" range for 2-speed motor with Dahlander windings, 3-phase 400V
" input/output terminals for manual triggering devices current break (opening dry contact)

Dans la boutique



En Export Aldes Manual Trip Device 11044121
En Export Aldes Manual Trip Device 11044121
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11044121 Manual trip device The manual trip device is used in a smoke and heat exhaust system in multi-occupancy housing. Manual trip device PRODUCT BENEFITS " compliance: NF-S 61936, " easily identified red box, " simple and fast to install. Principles of operation The manual activation device is used to report the outbreak of a fire. Once activated manually, it reports the information to the smoke exhaust control...

En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
En Export Aldes Parkone Car Park Unit Dah Hs 50 58a Ls 16 24a 11057538
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057538 ParkONE car park unit DAH HS 50-58A LS 16-24A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 1 6 A 11057529
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057529 ParkONE car park unit DAH HS 2.5-4 A LS 1-1.6 A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust unit PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed; comfort Product...

En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
En Export Aldes Parkone Car Park Unit Dah Hs 20 25a Ls 9 12a 11057535
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057535 ParkONE car park unit DAH HS 20-25A LS 9-12A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
En Export Aldes Parkone Car Park Unit Dah Hs 2 5 4 A Ls 1 6 2 4a 11057530
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057530 ParkONE car park unit DAH HS 2.5-4 A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
En Export Aldes Parkone Car Park Unit Dah Hs 6 3 10a Ls 2 4 4a 11057532
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057532 ParkONE car park unit DAH HS 6.3-10A LS 2.4-4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
En Export Aldes Parkone Car Park Unit Dah Hs 16 20a Ls 4 6a 11057534
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057534 ParkONE car park unit DAH HS 16-20A LS 4-6A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...

En Export Aldes Parkone Car Park Unit Dah Hs 4 6 3a Ls 1 6 2 4a 11057531
En Export Aldes Parkone Car Park Unit Dah Hs 4 6 3a Ls 1 6 2 4a 11057531
25/07/2024 - assets.aldes.com
1 SMOKE AND HEAT EXHAUST HOUSING Smoke exhaust dampers and air inlets 11057531 ParkONE car park unit DAH HS 4-6.3A LS 1.6-2.4A The residential car park smoke and heat exhaust units control the 2-speed axial fans for ventilation, smoke and heat exhaust. ParkONE car park smoke and heat exhaust system unit for multi- PRODUCT BENEFITS " Programmable timer to meet ventilation needs while saving energy " 3-position switch used to control the box: stop; forced smoke and heat exhaust and high speed;...
 

20231205 Wedi 40 Jahre Fotos
20231205 Wedi 40 Jahre Fotos
15/07/2024 - www.wedi.net
Bildmaterial 40 Jahre wedi  Fabian Rechlin, Geschäftsführer von wedi im Gespräch www.wedi.net/presse/40-jahre-wedi Fabian Rechlin, Geschäftsführer von wedi Die wedi Produktionsstätte an der Unternehmenszentrale in Emsdetten Die wedi Unternehmenszentrale in Emsdetten Die Zeitpläne auf den Baustellen sind eng getaktet, und die Personaldecke in vielen Betrieben ist angespannt. Hier punktet das neue Sanwell Duschwand-Modul: Die Rohre für die Kalt- und Warmwasserleitung sind enthalten,...

Ki 108 Schliessbleche Fl
Ki 108 Schliessbleche Fl
23/09/2024 - www.forster-profile.ch
@ 108-14/INT new forster Einfachere Justierung der Verriegelung des Gang-/Standfl?gels f?r Forster fuego light. Ajustement simplifi? du verrouillage des vantaux ouvrants et fixes Forster fuego light. Easier lock adjustement of the active and inactive door leaf for Forster fuego light. " Neue mehrfach verstellbare Schliessbleche " Ideal bei schweren Fl?gelgewichten " Mehr Flexibilit?t dank stufenloser Verstellbarkeit in alle Richtungen " Sicherer Sitz durch Verzahnung " Austausch bestehender...

Dscale NL UK FR IT PL ES
Dscale NL UK FR IT PL ES
19/06/2024 - aosmithinternational.com
DSCALE 0307565 / R1.0 Ontkalkingsinstructies Descaling instructions Instruction de détartrage Instruzioni per l'eliminazion del calcare Instrucciones de descalcificación Instrukce pro dekalcifikaci Gegevens onderhevig aan verandering. Data is subject to change. A.O. Smith Europe De Run 5305 PO Box 70 5500 AB Veldhoven The Netherlands Données sujettes à révision. Dati soggetti a modifica. Datos sujetos a cambios. 1 Introduction Dscale is a powerful color coded descaler. Dscale removes...


08/10/2024 - www.ondex.com
Résumé en cours de création pour ce fichier PDF

RGB BOOSTER DPV 3 ENC 24
RGB BOOSTER DPV 3 ENC 24
27/10/2010 - www.agabekov-lighting.com
RGB-BOOSTER DPV-3-ENC-24 RGB-BOOSTER DPV-3-ENC-24 RGB-BOOSTER DPV-3-ENC-24 RGB-DMX DIMMER PWM-3-ENC-24 RGB-DMX DIMMER PWM-3-ENC-24 RGB-DMX DIMMER PWM-3-ENC-24 C A B A C B Caractéristiques · Amplificateur RGB pour le fonctionnement synchrone de nombreux modules flexibles RGB-LIGHT avec le SPW-3-ENC-24 · Tension alimentation: 12...24V DC (SELV); max 6A; courant sans charge 15mA · Entrées: PWM-signal; 3 canaux; 15mA par canal · Sorties: PWM signal; 3 canaux; 12...24V DC ent. 2A courant continue...

T35100
T35100
09/12/2014 - www.bobcat.eu
T35100 Telescopic Handlers T35100 Hydrostatic with electronic regulation 2-speed hydrostatic motor Engine Make / Model Fuel / Cooling Rated power (DIN 6271) at 2200 RPM Maximum torque at 1400 RPM Number of cylinders Displacement Hydraulic System PERKINS / 1104D-44TA turbo Diesel / Liquid 74.5 kW (100 HP) 410 Nm 4 4.4 l 10.7 s 5.8 s 10.4 s 10.5 s 11.4 s 11.4 s Engine braking Parking and emergency brake Hydrostatic Negative brake with hydraulic command Axles and reduction gears front /...