Whitepaper Reducing Energy Use Airstream Heat Gain And Condensate Production

Extrait du fichier (au format texte) :

Steam humidification:
Reducing energy use, airstream heat gain, and condensate production

Updated!
Includes analysis of stainlesssteel-shielded dispersion tubes.

by Lynne Wasner and Jim Lundgreen,
Senior Mechanical Design Engineer
DRI-STEEM Corporation
Enlightened building owners demand accountability for every resource consumed in the construction and operation of new or renovated buildings. Meeting conservation benchmark standards requires measurable building performance, for it is commonly understood that if you can't measure it you can't improve it.

FIGURE 1-1:
TYPICAL DISPERSION ASSEMBLY

Commercial and industrial steam humidification is considered essential for most process, preservation, and health applications such as semiconductor manufacturing, printing plants, museums, schools, and health care facilities. Given the significant number of large buildings requiring steam humidification, it is time to make strides toward measuring and improving the energy efficiency and water consumption of these building systems. Recent advances in materials and manufacturing techniques are bringing attention to this issue,
specifically the energy and water wasted when dispersing steam into cool airstreams. This article describes these materials and includes data about their performance.

Steam dispersion basics
Humidifying with steam requires two essential functions: steam generation and steam dispersion.
Direct steam injection humidification systems disperse steam into duct or AHU airstreams from on-site boilers or unfired gas or electric steam generators. Unique to direct steam injection applications is the dispersion of pressurized steam.
Humidification steam can also be generated in a nonpressurized gas or electric steam generator connected to a dispersion assembly. This type of steam is often called
evaporative  steam because the steam chamber operates at or near atmospheric pressure.

Shown here is a typical steam dispersion tube panel with uninsulated stainless steel tubes installed to span the full height

Dans la boutique



White Paper Evaporative Humidification And Cooling For All Climates North America
White Paper Evaporative Humidification And Cooling For All Climates North America
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WHITE PAPER EVAPORATIVE HUMIDIFICATION AND COOLING FOR ALL CLIMATES WHY HUMIDIFY  AND WHY CONSIDER EVAPORATIVE TECHNOLOGY? Facility managers, owners and operators humidify their buildings for many reasons  the most common being the health of the people in the building and to protect equipment or products from dry air. Of course, humidification has a cost to operate. Evaporative humidification and cooling, regardless of the climate, can be the most cost-effective way to keep your building healthy,...

Humidification Handbook
Humidification Handbook
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
HUMIDIFICATION HANDBOOK Fifth Edition 2 DRISTEEM HUMIDIFICATION HANDBOOK Humidification Handbook FIFTH EDITION BERNARD W. MORTON AND DRI-STEEM CORPORATION DRISTEEM HUMIDIFICATION HANDBOOK 3 Copyright © 2019 by Bernard W. Morton and DRI-STEEM Corporation All rights reserved. No part of this publication may be reproduced or transmitted, in any form or any means, without the written permission of the company. Printed and bound in the United States of America. First printing June 1998. DRI-STEEM...

Whitepaper Reducing Energy Use Airstream Heat Gain And Condensate Production
Whitepaper Reducing Energy Use Airstream Heat Gain And Condensate Production
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Steam humidification: Reducing energy use, airstream heat gain, and condensate production Updated! Includes analysis of stainlesssteel-shielded dispersion tubes. by Lynne Wasner and Jim Lundgreen, Senior Mechanical Design Engineer DRI-STEEM Corporation Enlightened building owners demand accountability for every resource consumed in the construction and operation of new or renovated buildings. Meeting conservation benchmark standards requires measurable building performance, for it is commonly...

High Pressure System Data Center Case Study
High Pressure System Data Center Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
High-pressure system case study Data center humidification and cooling DriSteem system reclaims water from air handlers while it humidifies and cools a data center RESULTS " Maintains constant minimum humidity levels in a 130,000-square-foot server room with 35-foot ceilings " Reduces the building's cooling load by over 200 tons at peak demand " Reprocesses drain water from air handlers while producing no wastewater GUARANTEED SITE CONDITIONS This data center* provides colocation services, where...

Wts Handbk En
Wts Handbk En
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WATER FUNDAMENTALS HANDBOOK First Edition ii DRISTEEM WATER FUNDAMENTALS HANDBOOK Water Fundamentals Handbook First Edition Steve Felber DRISTEEM WATER FUNDAMENTALS HANDBOOK iii Copyright © 2017 by DRI-STEEM Corporation All rights reserved. No part of this publication may be reproduced or transmitted, in any form or any means, without the written permission of the company. Printed and bound in the United States of America. First printing September 2017. DRI-STEEM Corporation 14949 Technology...

White Paper Using A Specification Library For Humidification Projects
White Paper Using A Specification Library For Humidification Projects
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WHITE PAPER USING A SPECIFICATION LIBRARY FOR HUMIDIFICATION PROJECTS EXECUTIVE SUMMARY Architects, designers and other specifiers use 3-D models from product manufacturers  files that contain all the relevant data needed to make a decision about a building product. It's critical that these specifiers have access to online tools that allow them to research products and connect with building product manufacturers. With more government agencies requiring traceability in building design, including...

White Paper Using Dricalc To Confidently And Easily Specify And Select Humidification Systems
White Paper Using Dricalc To Confidently And Easily Specify And Select Humidification Systems
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WHITE PAPER USING DRICALC® TO CONFIDENTLY AND EASILY SPECIFY AND SELECT HUMIDIFICATION SYSTEMS EXECUTIVE SUMMARY Humidification is an integral part of many of today's HVAC systems. The fundamental principles of humidification are well documented, but the intricacies of how humidification systems work within the context of a complex HVAC system, and the vast array of humidification options, can be daunting even for a seasoned HVAC Engineer. DriSteem is a world leader with over 50 years of expertise...

Commercial Display Graphics Case Study 1116
Commercial Display Graphics Case Study 1116
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
High-pressure system case study Commercial display graphics DriSteem helps improve print consistency for a national leader in commercial display graphics RESULTS " Lowered the reject rate for large-format digital press output from 14 percent to 2.5 percent " Lowered the customer's electricity consumption enough to qualify for a significant utility rebate THE JOB Modernistic is one of the nation's leading suppliers of commercial display graphics and industrial OEM products. The company, headquartered...
 

Fpr Pe Select 46 020 Tubfr 2074 B
Fpr Pe Select 46 020 Tubfr 2074 B
23/08/2024 - www.tubauto.fr
FICHE PRODUIT Porte d'entrée - Select 46 020 Porte d'entrée élégante et moderne en acier et aluminium, en dimensions standards et sur-mesure Hautes performances techniques : Isolation thermique optimale jusqu'à 1,4 W/m².K. Double vitrage. Etanchéité parfaite grâce à sa double ligne de joints. Sécurité face aux tentatives d'intrusion : Serrure automatique à rouleaux à verrouillage 5 pênes. Dispositif d'anti-dégondage. Possibilité de contacts intégrés pour raccordement à une...

Especificaciones de la fresadora
Especificaciones de la fresadora
01/12/2010 - www.bobcat.eu
Fresadoras Implementos Fresadoras Especificaciones técnicas Ventajas Aplicaciones Equipada con tracción directa y motor hidráulico de par alto, este implemento, que requiere poco mantenimiento, fresa eficazmente asfalto u hormigón. Las fresadoras presentan un desplazamiento lateral hidráulico para trabajar en zonas cercanas a paredes o bordillos. Cuentan asimismo con un control de profundidad para que el fresado sea homogéneo y con patines con profundidad visible desde el asiento del...

Fireplaces - Tulikivi
Fireplaces - Tulikivi
16/03/2020 - www.tulikivi.com
ENG Wood www.tulikivi.com 1 FRA Le bois GER Das Holz NED Hout ITA La legna Fireplaces ENG Wood: an economical and environment-friendly fuel... ... if put to clever use! WOOD IS AN ENVIRONMENT-FRIENDLY FUEL  ESPECIALLY WHEN USED IN YOUR TULIKIVI The amount of CO2 emitted when you burn wood in your Tulikivi is the same as when wood decomposes naturally in the forest. The same quantity of CO2 is extracted from the air for photosynthesis when the tree is growing. This maintains a kind...

Anti Balle Page Par Page
Anti Balle Page Par Page
15/08/2024 - www.macocco.com
PLASTOFLOAT ANTI-BALLES PROTECTION GARANTIE Verre feuilleté de protection contre les tirs d'armes à feu Les Plastofloat anti-balles sont des verres feuilletés de sécurité obtenus par laminage de plaques de verre et de films intercalaires en butyral de polyvinyle avec, pour les verres feuilletés anti-balles composites, adjonction de polycarbonate et de films en polyuréthane. Une gamme étendue enrichie par 50 années d'expérience Les différentes compositions que nous proposons ont été...

PV Euroclasse Triso Protec
PV Euroclasse Triso Protec
25/11/2010 - www.actis-isolation.com
Comme décrit dans le rapport de classement 2006-CVB-R0270, dont le commanditaire est: Actis Avenue de Catalogne 11300 LIMOUX France, Le classement réaction au feu effectué conformément à l'article 8.2 de EN 13501-1 de TRISO PROTEC, est B-s1, d0 Cette classification est effectuée sur la base de résultats d'essais selon les normes: NF EN 11925-2 : 2002 NF EN 13823 : 2002 Description de produit: Le produit se compose de plusieurs couches de: - film métallisé armé - ouate de polyester -...

Dossier chantier INFLUENCE
Dossier chantier INFLUENCE
28/05/2018 - www.clipper.fr
Dossier chantier INFLUENCE JOINDRE IMPERATIVEMENT UN PLAN AVEC CÔTES DE REFERENCES OU UN SCHEMA CÔTE Nom du chantier Société/Entreprise / Date / Agence Commercial agence Hauteur sous plafond Couleur Ossature Blanc I7 Couvre joint Gamme Raccords 3D I Nov bord à bord I Fil joints creux vertical I9 joint creux multi-volumes Nombre de volume : Meneau plein Epaisseur Feuilletés Stores 25 mm (REF : ) Simple Attention : Anodise Angle droit 3D