Overvoltage products Main power supplies
Transient overvoltages VE range Modular cabinets - 230/400 V~ networks Protection of an industrial site with a very high lightning risk level
Example based on the same site with an IT+N earthing system (refer to previous diagram).
Protection Protection type Network type SPD Backup protection Cabinet Dry contacts
1

HVLV transformer None

Main Board (Bg.1)1 production, stocks, ... F protection T1-25 / IT+N system 230 / 400 V three phase ASS3314T1 (x4) ASS5125FU (x4) ASM9400VE ASS9400CA

DB1 Building 1 offices, computer rooms G protection T2-C1D / IT+N system 230 / 400 V three phase ASS8214A2 ASS5015DQ ASN9200VE ASS9200CA

DB Building 2 Security building G protection T1-12.5 / IT+N system 230 / 400 V three phase ASS1118A1 ASS5015DQ ASM9200VE ASS9200CA

Building 22 Alarm & control system G protection T2-M / IT+N system 230 V single phase ASS4204T2 (x2) ASS2515DD ASN9200VE ASS9200CA

The HVLV transformer protection being not implemented, the MB protection is reinforced with a SPD type 1 with Iimp = 25 kA. 2 Single phase protection similar to G protection (with 2 poles protection).

Protections F
L1
PG 13

Protection G
L1
PG 13

Protection H
L1
PG 13

L2
PG 13

L3
PG 13

N
PG 1 3

L2
PG 13

L3
PG 13

N
PG 13

L2
PG 13

Dans la boutique



pdf page 72
pdf page 72
09/04/2011 - www.franklin-france.com
Overvoltage products Main power supplies Transient overvoltages Modular cabinets - VE range - 120/208 V and 230/400 V~ networks Surge protective devices guideline (1) The installation of the surge protective devices should be done in compliance with the electrical safety rules of the electrical standards NF C 15-100, IEC 60364 or all equivalent electrical standard in the country. As for all electrical equipments, their installation should be done according to the electrical safety rules, for the...

pdf page 47
pdf page 47
09/04/2011 - www.franklin-france.com
Produits foudre Mâts supports et fixations Mâts rallonges Franklin pour paratonnerres à tiges Les mâts rallonges Franklin, constitués d'éléments de 2 mètres, s'emboîtent par recouvrement évitant le boulonnage et le ruissellement de l'eau à l'intérieur, sources de corrosion prématurée. De très grandes résistances, il est possible d'associer 3 mâts sur trépied sans haubanage pour une vitesse du vent pouvant atteindre 160 km/h. Ils sont livrés avec les colliers d'attache des conducteurs....

pdf Blunt Tip Lightning Rod
pdf Blunt Tip Lightning Rod
09/04/2011 - www.franklin-france.com
Lightning Conductors Lightning rods NF C 17-100, IEC 1024 AFA 0001 PF Simple lightning rod " Franklin " Blunt Tip Type Franklin lightning rod, which are blunt tip tapered, have a perfectly slender and attractive point. They exist in nickel/chromium-plate copper and stainless steel versions. They have a standard length of 2,4m and can be extended by the addition of treated steel and stainless steel elevation rods. These systems do not require guying and can be up to 7 or 8 m long. The tip of 2F...

pdf page 97
pdf page 97
09/04/2011 - www.franklin-france.com
Produits associés Systèmes de prévention Systèmes autonomes pour réseaux d'énergie Réseaux 230/400 V~ - Tout régime de neutre Coffrets de protection pour réseaux stratégiques Normes : CEI 61643-1/2002, EN 61643-11 (NF C 61-740), NF C 15-100, NF EN 60950, 50081-1 et 50082-1 Description Ces coffrets sont destinés à la protection des équipements très sensibles des réseaux stratégiques alimentés. Totalement autonomes, ils protègent les équipements par la déconnexion ultra rapide...

pdf page 76
pdf page 76
09/04/2011 - www.franklin-france.com
Overvoltage products Main power supplies Transient overvoltages VE range Modular cabinets - 230/400 V~ networks Protection of an industrial site with a very high lightning risk level Example based on the same site with an IT+N earthing system (refer to previous diagram). Protection Protection type Network type SPD Backup protection Cabinet Dry contacts 1 HVLV transformer None Main Board (Bg.1)1 production, stocks, ... F protection T1-25 / IT+N system 230 / 400 V three phase ASS3314T1 (x4) ASS5125FU...
 

ABCD News Portes Clarit
ABCD News Portes Clarit
12/12/2010 - www.abcd-international.fr
Edition Mai 2007 Suite au succès rencontré lors de la précédente opération l'année dernière, ABCD réitère cette offre exceptionnelle : La porte Clarit® clair claire L. 827 x 2034 H. à 65.00* Quelle que soit la quantité. uisement Offre valable jusqu'à épuisement du stock (300 portes) D'un aspect clair, design et indémodable, elle saura séduire vos clients. Contrairement aux idées reçues, la porte Clarit® est moins fragile qu'une porte bois stratifiée. Elle peut donc être facilement...

PLINTO Fiche Technique Et Conseils De Pose
PLINTO Fiche Technique Et Conseils De Pose
19/09/2024 - www.carodeco.com
LIGNE ZELLIGE CERAME PLINTO CONSEILS DE POSE STOCKAGE Pour garantir les caract?ristiques et finitions du produit, il doit ?tre conserv? dans son emballage d'origine jusqu'? la pose. Si le produit doit rester stock? pendant une longue p?riode il doit ?tre convenablement couvert. POSE Pose murale. Pour s'assurer que les produits adh?rent correctement au support, il est n?cessaire d'utiliser du mat?riel de collage et de jointoiement sp?cifique qui doit ?galement ?tre adapt? ? l'environnement auquel...

Technical Data Classicboard P2 Carb2 Im0016408
Technical Data Classicboard P2 Carb2 Im0016408
16/08/2024 - www.pfleiderer.com
August 2024 Technical data ClassicBoard P2 CARB2 Tolerance on thickness ± 0.3 mm Tolerance on length (EN 324-1) ± 5 mm Tolerance on width (EN 324-1) ± 5 mm Straightness of edges (EN 324-2) 1.5 mm/m Squareness (EN 324-2) 2 mm/m Moisture content (EN 322) 9%±4% Formaldehyde emission class E1 E05 CARB Phase 2 / TSCA Title VI 1 Requirement Property Test method Thickness / Range of thickness (mm, nominal dimension) Unit "d 8.9 > 8.9 to "d 13

.cata 2005 OKKKK
.cata 2005 OKKKK
10/03/2012 - kaufelfr.tnb.com
COFFRETS D'ÉNERGIE PERMANENT UTILISATION - Permanent : secteur présent. - Secours : secteur absent. Coffret mural pour l'alimentation permanente d'un circuit d'utilisation nécessitant une tension à courant continu 12/24/48 V secteur présent et secourue sur disparition secteur suivant l'autonomie. CARACTERISTIQUES Ces coffrets sont alimentés à partir d'un secteur monophasé 230V/50 Hz comprenant : - 1 chargeur redresseur filtré à tension constante 12/24/48 V, régulation ± 1 %, filtrage...


22/10/2024 - onip.com
Résumé en cours de création pour ce fichier PDF

p2m
p2m
09/04/2011 - www.outinord.fr
www.outinord.fr P2M Mise en oeuvre rapide Une gamme dimensionnelle étendue Utilisation en grande hauteur Intégration rapide d'éléments spécifiques COFFRAGE POTEAU AILE DE MOULIN A LA MISE EN OEUVRE : Le P2M est pré assemblé en usine : panneau, ceinture, passerelle à trappe, échelle d'accès. Sa mise en oeuvre s'effectue sitôt son arrivée sur le chantier. AU DECOFFRAGE : Seulement six écrous à ailettes sont à enlever pour décoffrer un poteau. Le décoffrage par demi poteau est donc...