Datenblatt mcDSA E4

Extrait du fichier (au format texte) :

mcDSA-E4 / mcDSA-E4-HC
Motion Control · · · · · · ·
Very compact 4-quadrant controller to control brushtype, brushless DC-motors and linear motors Freely programmable with integral Motion Process Unit. Allows stand-alone operation and stand-alone networks CAN interface (DSP402) The controller has over-voltage, low-voltage and overtemperature monitoring With display "power", "status" and "error" The controller can be fixed by a hut-rail (35 mm) or fixing clips Three connection plugs are included in delivery

miControl
Pin assignment / Anschlussbelegung

®

Antriebsregler · · · · · · ·
Sehr kompakter 4-Quadranten-Regler zur Ansteuerung von bürstenlosen, bürstenbehafteten DC-Motoren und Linearmotoren Frei programmierbar mit integrierter Motion Process Unit. Diese Ausführung ermöglicht auch Stand-alone-Betrieb und Vernetzung Mit CAN-Schnittstelle (Geräteprofil DSP402, Protokoll DS301) Die Elektronik verfügt über Überspannungs-,Unterspannungsund Übertemperaturüberwachung Mit Anzeige "Power", "Status" und "Error" Die Befestigung der Elektronik kann über eine Huttrageschiene (35 mm) oder auf Montageplatte erfolgen Die 3 Anschlussstecker sind im Lieferumfang enthalten

X1 Pin assignment / Pinbelegung
X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X2.1 X2.2 X2.3 X2.4 X2.5 X2.6 X2.7 X2.8 X2.9 X2.10 X2.11 PE +Up GND Ma Mb Mc H1 H2 H3 A B INX +U5V /H1 /H2 /H3 /A
earth/ Schutzerde

X2

X3 Pin assignment / Pinbelegung
X2.12 X2.13 X2.14 X3.1 X3.2 X3.3 X3.4 X3.5 X3.6 X3.7 X3.8 X3.9 X3.10 X3.11 X3.12 /B /INX GND +Ue 24V +AIN 0 DIN 0 DIN 1 DIN 2 DIN 3 GND -AIN 0 DOUT 0 CAN_HI CAN_LO CAN_GND
inc. encoder channel B inverted Inc- Encoder - Negierte Spur B inc. encoder index channel inverted/ Inc- Encoder - Negierter Index ground 0V for power supply hall/encoder/ Masse für Hall/Enc

For further technical data and information on terminal assignment, please see the operating manual at www.miControl.de (downloads).

Weitere technische Daten sowie Informationen zur Anschlussbelegung finden Sie in der Betriebsanleitung bei www.miControl.de (downloads).

power supply +10 .. +30V(DC) Spannungsversorgung Leistung +10 .. +30V(DC) ground 0V for power supply/ Masse Leistung motor phase A/ Motoranschluss A motor phase B/ Motoranschluss B motor phase C/ Motoranschluss C

power supply electronic +24V/ Spannungsversorgung Elektronik +24V plus analog input/ Plus analoger Eingang digital input 0/ digitaler Eingang 0 digital input 1/ digitaler Eingang 1 digital input 2/ digitaler Eingang 2 digital input 3/ digitaler Eingang 3 ground 0V for power supply electronic/ Masse Elektronik minus anlog input/ Minus analoger Eingang digital output 0/ digitaler Ausgang 0 CAN high/ CAN High CAN low/ CAN Low CAN ground/ CAN Masse

hall sensor 1/ Hallsensorsignal 1 hall sensor 2/ Hallsensorsignal 2 hall sensor 3/ Hallsensorsignal 3 inc. encoder channel A/ Inc. Encoder-Spur A inc. encoder channel B/ Inc. Encoder-Spur B inc. encoder index channel/ Inc. Encoder-Index power supply hall/encoder +5V Spannungsversorgung für Hall/Enc +5V hall sensor 1 inverted Negiertes Hallsensorsignal 1 hall sensor 2 inverted/ Negiertes Hallsensorsignal 2 hall sensor 3 inverted Negiertes Hallsensorsignal 3 Iinc. encoder channel A inverted Inc- Encoder - Negierte Spur A

Schweiz Angst + Pfister AG Thurgauerstrasse 66 Postfach CH-8052 Zürich Telefon 044 306 61 11 Telefax 044 302 18 71 www.angst-pfister.com

Suisse Succursale Suisse romande Route du Bois-des-Frères 52 Case postale 18 CH-1219 Genève-Le Lignon Téléphone 022 979 28 00 Téléfax 022 979 28 78 electricaldrive@angst-pfister.com

Dimensions in mm / Abmessungen in mm
Standardversion HC-Version Seitenansicht Standardversion / HC-Version

technical data / technische Daten
Master functionality (MPU integrated) Masterfunktionalität (MPU integriert) voltage electronic supply Versorgungsspannung Elektronik voltage power supply Versorgungsspannung Leistung current consumption @ 24V Stromaufnahme @ 24V peak output current Maximaler Ausgangsstrom continuous output current @ 40º C Zulässiger Dauerausgangsstrom @ 40º C digital input Digitale Eingänge digital output Digitale Ausgänge analog input Analoge Eingänge protection class Schutzart ambient temperature Umgebungstemperatur rel. humidity (non condensing) Umgebungsfeuchtigkeit (nicht kondensierend) weight Gewicht changes and mistakes reserved Änderungen und Irrtümer vorbehalten

mcDSA-E4
yes/ja V (DC) V (DC) mA A A 8,5...30 8,5...60 typ. 50 30 8* 4 1 1 (+/- 10V) IP 20 ºC % g 0...+70 20...80 110

mcDSA-E4-HC
yes/ja 10...30 10...60 typ. 50 30 14* 4 1 1 (+/- 10V) IP 20 0...+70 20...80 260
VNR: 062009

Dans la boutique



Siehe beiliegende Qualitätsnachweise
Siehe beiliegende Qualitätsnachweise
10/01/2011 - www.angst-pfister.com
Dokumente* Konformitätsbescheinigung des Herstellers 2.1 Konformitätsbescheinigung des Herstellers 2.2 Konformitätsbescheinigung des Herstellers 3.1 Konformitätsbescheinigung des Herstellers 3.2 Konformitätserklärung IMDS-Eintrag Erstmusterprüfbericht Erstmusterprüfbericht gemäss PPAP Stufe 3 Prüfprotokoll Norm EC 10204-2.1 EC 10204-2.2 EC 10204-3.1 EC 10204-3.2 EC ISO/IEC 17050 VDA 231-106 gemäss Kundenanforderungen ISO/TS 16949, VDA Band 2, QS 9000 Beschreibung Lieferbescheinigung...

Datenblatt mcDSA E4
Datenblatt mcDSA E4
10/01/2011 - www.angst-pfister.com
mcDSA-E4 / mcDSA-E4-HC Motion Control · · · · · · · Very compact 4-quadrant controller to control brushtype, brushless DC-motors and linear motors Freely programmable with integral Motion Process Unit. Allows stand-alone operation and stand-alone networks CAN interface (DSP402) The controller has over-voltage, low-voltage and overtemperature monitoring With display "power", "status" and "error" The controller can be fixed by a hut-rail (35 mm) or fixing clips Three connection plugs are included...

See included quality certifications
See included quality certifications
10/01/2011 - www.angst-pfister.com
Documents* Manufacturer certificate of compliance 2.1 Manufacturer certificate of compliance 2.2 Manufacturer certificate of compliance 3.1 Manufacturer certificate of compliance 3.2 Declaration of conformity IMDS entry Initial sample test report Initial sample test report in accordance with PPAP Level 3 Test protocol Norm EN 10204-2.1 EN 10204-2.2 EN 10204-3.1 EN 10204-3.2 EN ISO/IEC 17050 VDA 231-106 pursuant to customer requirements ISO/TS 16949, VDA volume 2, QS 9000 Description Certification...

2023 Sustainability Report
2023 Sustainability Report
14/07/2024 - www.angst-pfister.com
SUSTAINABILITY REPORT 2023 ANGST+PFISTER GROUP Angst+Pfister Group - Sustainability Report 2023 Your Innovation Development Partner Angst+Pfister Group, headquartered in Zurich, is a globally operating enterprise with wholly owned subsidiaries and presence across Europe, Asia and the US, that engineers and produces innovative industrial components. Angst+Pfister continuously develops components based on innovation along the value chain, from material design and compounding, to engineering,...

Vedere le certificazioni di qualità incluse
Vedere le certificazioni di qualità incluse
10/01/2011 - www.angst-pfister.com
Documenti* Attestato di conformità 2.1 Attestato di conformità 2.2 Attestato di conformità 3.1 Attestato di conformità 3.2 Dichiarazione di conformità Iscrizione IMDS Rapporto di prova campione iniziale Rapporto di prova campione iniziale in conformità a PPAP livello 3 Registro di prova Norma EN 10204-2.1 EN 10204-2.2 EN 10204-3.1 EN 10204-3.2 EN ISO/IEC 17050 VDA 231-106 in conformità ai requisiti del cliente ISO/TS 16949, VDA volume 2, QS 9000 Descrizione Certificazione di fornitura in...

Datenblatt mcDSA F7
Datenblatt mcDSA F7
10/01/2011 - www.angst-pfister.com
mcDSA-F7 Motion Control · Very compact 4-quadrant controller to control brush-type, brushless DC-motors and linear motors miControl Antriebsregler · Sehr kompakter 4-Quadranten-Regler zur Ansteuerung von bürstenlosen, bürstenbehafteten DC-Motoren und Linearmotoren ® Pin assignment / Pinbelegung - ACHTUNG! Alle reservierten Klemmen dürfen nicht angeschlossen werden X1.32 X1.30 X1.28 X1.26 X1.24 X1.22 X1.20 X1.18 X1.16 X1.14 X1.12 X1.10 X1.8 X1.6 X1.4 X1.2 X2.16 X2.14 -AIN 1 +AIN 1 RES RES...

mcDSA F7 profibus
mcDSA F7 profibus
10/01/2011 - www.angst-pfister.com
mcDSA-F7-profibus Motion Control · Very compact 4-quadrant controller to control brush-type, brushless DC-motors and linear motors miControl Antriebsregler · Sehr kompakter 4-Quadranten-Regler zur Ansteuerung von bürstenlosen, bürstenbehafteten DC-Motoren und Linearmotoren ® Pin assignment / Pinbelegung - ACHTUNG! Alle reservierten Klemmen dürfen nicht angeschlossen werden X1.32 X1.30 X1.28 X1.26 X1.24 X1.22 X1.20 X1.18 X1.16 X1.14 X1.12 X1.10 X1.8 X1.6 X1.4 X1.2 X2.16 X2.14 X2.12 X2.10...

mcDSA E4 optionen
mcDSA E4 optionen
10/01/2011 - www.angst-pfister.com
mcDSA-E4 Motion Control · · · · · · · Very compact 4-quadrant controller to control brushtype, brushless DC-motors and linear motors Freely programmable with integral Motion Process Unit. Allows stand-alone operation and stand-alone networks CAN interface (DSP402) The controller has over-voltage, low-voltage and overtemperature monitoring With display "power", "status" and "error" The controller can be fixed by a hut-rail (35 mm) or fixing clips Three connection plugs are included in delivery miControl Antriebsregler...
 


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

XL 800
XL 800
10/02/2012 - www.legrand.fr
3 XL 800 Coffrets et armoires de distribution CA H I E R D 'AT E L I E R Avec l'étendue de ses gammes, l'offre Legrand répond à vos exigences de qualité par une réelle liberté et une simplicité de mise en oeuvre associée à une fiabilité reconnue. Avec les coffrets et armoires XL3 800, Legrand a innové dans le concept d'intégration. Du coffret pour les tableaux divisionnaires à l'armoire pour TGBT, du répartiteur en gaine à câbles à la distribution optimisée XL-Part en fond...

Catalogue - Dirickx
Catalogue - Dirickx
16/01/2018 - www.dirickx.fr
!’ Documentations commerciales !’ Descriptifs et dessins techniques !’ Tableaux de dimensions !’ Notices d installation !’ Configurations de pose !’ Logiciel de plans de Génie Civil DIRICKX GROUPE - 53800 CONGRIER - FRANCE Tél. : 33 (0)2 43 09 38 38 - Fax : 33 (0)2 43 09 38 99 www.dirickx.fr Catalogue Catalogue Téléchargez sur notre site Internet toute l information sur nos produits et nos services : - DIRICKX se réserve le droit de modifier à tout moment ses photos afin...

CLIMAFLEX XT
CLIMAFLEX XT
09/04/2011 - www.nmc.be
CLIMAFLEX® XT Rohrisolierung aus geschlossenzelligem Schaum auf Basis von Polyethylen mit beidseitig selbstklebendem Verschlusssystem für den Einsatzbereich Heizung und Sanitär. bis zu 50% Zeitersparnis bei der Montage Produkteigenschaften Wärmeleitfähigkeit (DIN 52613 / EN ISO 8497): 0,036 W/mK bei 10 °C 0,040 W/mK bei 40 °C 0,053 W/mK bei 90 °C Brandverhalten: BLs2d0 (EN 13501-1) Temperatureinsatzbereich (EN 14707): bis +100 °C (+85 °C bei Bögen) Normen: EnEV-konform / DIN 1988 Teil...

Mo51824 Vers2 James Qi Sl A5
Mo51824 Vers2 James Qi Sl A5
17/07/2024 - www.oligo.de
OLIGO Lichttechnik GmbH Tannenweg 1 DE - 53757 Sankt Augustin Germany www.oligo.de info@oligo.de JAMES SLACK-LINE LADESCHALE Qi Art.-Nr. / Item-No. 62-851-20-XX DC 24V SELV max. 24W / 1A Spannung Belastung GB Voltage Loading NL Spanning Belasting F Tension Charge I Tensione Carico ES Tensión

Ag 30062021 Annonce 2102118 1
Ag 30062021 Annonce 2102118 1
25/06/2024 - www.rougier.fr
28 mai 2021 BULLETIN DES ANNONCES LEGALES OBLIGATOIRES Avis de convocation / avis de réunion 2102118 Page 1 Bulletin n°64 28 mai 2021 BULLETIN DES ANNONCES LEGALES OBLIGATOIRES Bulletin n°64 Convocation Assemblée Générale d'actionnaires et de porteurs de parts ROUGIER S.A. Société Anonyme à Conseil d'Administration au capital de 5 549 144,22 ¬, Siège social : 210, avenue Saint-Jean d'Angely  79000 NIORT, 025 580 143 R.C.S. Niort. AVIS DE REUNION VALANT AVIS DE CONVOCATION Mesdames...