Brochure

Extrait du fichier (au format texte) :

BATTERY CHARGER
D.C POWER SUPPLY

CPN, HP, HPT series

A U T O M A T I S M E S

E N E R G I E

E L E C T R O N I Q U E

S Y S T E M E S

PRELIMINARY
AEES Company, specialist in emergency power supply for various applications provides a wide range of products. The charger rectifier is the common part of all these systems.

CHARGER
LOW RATING CHARGER for stationnary battery CE-CN.D-CPN.D/E-CMV Series 20039 leaflet UNINTERRUPTIBLE POWER ASD-ASC SERIES 20040 - 20050
LEAFLETS SUPPLY

RECTIFIER

DC FUNCTIONALITY
RELIABILITY PERFORMANCE STANDARD OR CUSTOM DESIGN

POWER SUPPLY

WITH BATTERY

IPP - ISP- ISPP - SPP Series 20043 - 20044 leaflets EMERGENCY LIGHTING EPP-ESP-PCC-SCC Series 20079 - 20080 leaflets DC
POWER SUPPLY

BATTERY

CHARGER UNIT

CPN-HP-HPT series : this 20046 leaflet is dedicated to them

REFERENCES
APPLICATIONS : Automatisms (relays, PLC...) Telephone exchanges (PABX) Switchboards for LV, MV, HV, Switchgears Emergency lighting Computers, data processings Alarm systems Machines (ticketing - tooling...) etc... USES : Transport (Subway, airport, railways...) Telecommunications Industry (oil, chemical, car...) Marine (Veritas, Lloyds...) Army Buildings (Sky scraper, commercial center...) O.E.M. Exportation (5 mainlands).

SYNOPTIQUE
INPUT MAINS

OUTPUT

EQUIPMENT
1 Overload and short circuit protection : Circuit breaker ......................................................................................................................... Fuse ........................................................................................................................................ 2 Pre-magnetization circuit (Rush of current limitation) ............................................................................. 3 Surge suppressor according to CEI 801.5. ............................................................................................. 4 Incoming circuit contactor ...................................................................................................................... 5 Input transformer ..................................................................................................................................... Regulated rectifier module including : 6 Diodes / thyristors bridge rectifier. ............................................................................................. 6 pulses rectifier bridge ............................................................................................................. «MCD» type rectifier bridge system providing same performances as a 12 pulses rectifier, but with higher reliability. As example (N version) : - Cos 0,92 - THD (current) 15%........................ 7 Electronic control unit. .............................................................................................................. 8 Smoothing unit : - Standard : LC type ................................................................................................................. - Improved : type .................................................................................................................. 9 Output voltage limitation : - Transistorized ballast .............................................................................................................. - Diodes dropper ...................................................................................................................... Overload and short circuit protection 10 Output circuit : fuse ......................................................................................................... Circuit breaker .......................................................................................... 11 Battery circuit : fuse isolator (Depending on configuration) ................................................. Circuit breaker .......................................................................................... 12 Battery temperature sensor for U = f () regulation ..................................................................................... 13 Line voltage drop compensation device (far away battery, high power supply...) ......................................... 14 Earth fault monitor (CPI) ............................................................................................................................ 15 Voltage monitoring of charger voltage ........................................................................................................ Voltage monitoring of battery voltage ......................................................................................................... Voltage monitoring of output voltage ......................................................................................................... 16 Charger switch-off when over battery voltage ............................................................................................ 17 Output switch-off when under battery voltage ........................................................................................... 18 « on-off » switch ........................................................................................................................................ 19 Remote control of the charger (for instance to enslave the charge operation, to the battery room ventilation) ..... 20 Switch or push button for manual charge control ......................................................................................... 21 Selector for Charge mode - Automatic mode - Manual mode ....................................................................... 22 Voltage selector for multi voltages system .................................................................................................... 23 Ajustable output voltage by potentiometer .................................................................................................. 24 Push button faults reset .............................................................................................................................. Signalling by L.E.D. or signal lamp (S) and free remote contact (R) : 25 A.C. healthy ............................................................ 26 Charge on .............................................................. 27 Charger fault .......................................................... 28 Charger voltage fault (overvoltage) ..................... 29 Battery voltage fault (undervoltage) .................... } 30 Earth fault ............................................................... 31 Manual charge on ................................................. Meters (72 x 72 - 90° scale) : 32 Charger flow ...................................................................................................................................................... 33 Output flow ........................................................................................................................................................ 34 Charge and discharge battery current ........................................................................................................... 35 Output voltage or battery voltage ................................................................................................................... 36 Input voltage ..................................................................................................................................................... 37 Digital indicator against moving coil indicator .................................................................................................................. 38 U and I measuring tansducers ........................................................................................................................................... 39 Man-machine communication-unit, maintenance aid, battery supervising, remote transmission ............................ 40 Interface (RS 232 - RS 485 - RS 422) ............................................................................................................................... 41 Automatic battery test device ............................................................................................................................................ 42 Additional outgoing feeders by circuit breakers ............................................................................................................... 43 Special make following specification ................................................................................................................................

CPN A B

Dans la boutique



Plaquette / Brochure
Plaquette / Brochure
27/10/2010 - www.aees.fr
CHARGEUR DE BATTERIE (TÉLÉPHONIE/SÉCURITÉ) RECTIFIER BATTERY CHARGER (PABX) Série JUPITER 500 JUPITER 500 Series A U T O M A T I S M E S E N E R G I E E L E C T R O N I Q U E S Y S T E M E S ALIMENTATION A COURANT CONTINU CHARGEUR DE BATTERIE POUR : BAIES TÉLÉPHONIQUES (MOYENNE CAPACITÉ). ÉQUIPEMENTS SENSIBLES (RADIO, PROCESS). Conformité Normes CEM (Directive n° 89/336/CEE) : - faible réjection harmonique, - haute immunité. Appareil très complet avec de très nombreuses fonctionnalités...

Certificat E 9997 3
Certificat E 9997 3
27/10/2010 - www.aees.fr
DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-9997 This Certificate consists of 3 pages This is to certify that the Constant Voltage Charger with type designation(s) CMV Holder of certificate Automatismes Energie Electronique Systèmes Saint Priest Cédex, France is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application Voltage output Power Temperature class Vibration class Humidity...

sources centralis”es 6H - AEES
sources centralis”es 6H - AEES
05/12/2017 - www.aees.fr
SOURCES CENTRALISEES 6 HEURES POUR E.R.P. AVEC LOCAUX A SOMMEIL PCC 30C-6H EPP 48 650-6H APPLICATION Les sources centralisées EPP à courant continu de 300W à 1,5kW et PCC à courant alternatif de 600VA à 4,5kVA autonomie 6 HEURES sont réglementairement préconisées pour l alimentation des installations d éclairage de sécurité des Etablissements Recevant du Public (E.R.P.) de toutes catégories avec locaux à sommeil ne disposant pas de source de remplacement à partir d un groupe...

stabilisateurs de tension monophasée et triphasée - AEES
stabilisateurs de tension monophasée et triphasée - AEES
05/12/2017 - www.aees.fr
STABILISATEURS DE TENSION MONOPHASÉE ET TRIPHASÉE SINGLE AND THREE PHASES VOLTAGE STABILIZERS STMV STYO APPLICATIONS/APPLICATIONS Les stabilisateurs de tension électrodynamiques permettent de réguler les tensions instables sur les réseaux monophases (STM) ou triphasés (STT), avec dissymétrie des tensions entre phases et/ou charges fortement déséquilibrées (STY). The automatic voltage regulators provide voltage stabilisation from instable networks single phase (STM) or three phases...

E.NOV 5
E.NOV 5
27/10/2010 - www.aees.fr
L E T T R E D ' I N F O R M A T I O N S P R O D U

Acces
Acces
27/10/2010 - www.aees.fr
!" $ # % ! ! &'( % !" !" $ ) * +" # !" * ,& ( % % % # $ ' % !" % # $ ) %& -) * ( . +" !" * * # $ % & % %' % % !" /" % " # *# *01 *0 (2 ) 3 '(. ( , * ( 4 #() ( 5( * 4 * - " % ( ( - ( & ' ( #$ 6"7 ( ())* (* + # , - . /01 /2 ! ( % %& 8 ! &'( 7 ( 4 * +!, % ' % % ./ 0 " ! ( , 9 '( / ())* # , - 01 /2 $

astus habitation - AEES
astus habitation - AEES
05/12/2017 - www.aees.fr
ASTUS HABITATION Bloc Autonome d Eclairage d Habitation (BAEH) 1 Description BAEH d évacuation IP43 / 65  IK08 10 lm  5h 100% LED Classe II Consommation 1,1W / 1,7VA Performance SATI Caractéristiques techniques Montage Encastré ou Saillie, en mural ou plafonnier Dimensions : L 250 x l 127 x P 67 mm Poids : 575 g Pack batterie 2 éléments : type Ni Cd 2,4V  650mAh Matériaux Enveloppe design au modèle déposé Socle universel et Verrine sur charnières : PC Support composant : PP + Etiquettes...

FICHE PCCE 20208 definitive V2
FICHE PCCE 20208 definitive V2
27/10/2010 - www.aees.fr
E sources centralisées | luminaires | blocs autonomes PCCE PCCE PCCE est une source centrale pour l'alimentation des luminaires (LSC) de sécurité des Etablissements Recevant du Public (ERP) et/ou des Travailleurs (ERT). Sa gamme de puissances convient particulièrement aux établissements où le nombre de points lumineux est élevé, c'est-à-dire où les parties communes sont nombreuses ou très étendues. PCCE apporte à votre système d'éclairage de sécurité des rendements améliorés...
 

Chargeuses compactes sur chenilles
Chargeuses compactes sur chenilles
14/02/2012 - www.bobcat.eu
T110 Chargeuses compactes sur chenilles Un concentré de puissance La chargeuse Bobcat T110 est la chargeuse sur chenilles la plus compacte du marché. D une maniabilité hors pair, elle constitue le partenaire idéal de tous vos travaux d aménagement paysager et de construction. Rien ne l arrête ! Elle se faufile dans les ouvertures étroites, circule entre les obstacles et évolue avec aisance dans tous les endroits où l espace fait défaut. Gagnez en productivité tout au long de...

AUTOTESTABLE SATI
AUTOTESTABLE SATI
10/03/2012 - kaufelfr.tnb.com
100% LED BRIO+ ET 10L A Référence : 246 703 AUTOTESTABLE SATI HABITATION NON PERMANENT ETANCHE Photo non contractuelle Compatible avec les principales télécommandes du marché Label « Performance SATI » Bloc design extra-plat < 42 mm Technologie 100% LED Consommation < 1 W Garantie commerciale 3 ans CARACTERISTIQUES TECHNIQUES : Numéro d'homologation : Indice de protection : Flux assigné : Autonomie : Classe : Dimensions (Lxlxh) : Tension d'alimentation : T09103 IP65 / IK 10 8 lm 5...


28/09/2024 - www.vescom.com
Résumé en cours de création pour ce fichier PDF

Pour isoler les combles perdus par soufflage dans les règles de l'art, Knauf Insulation invite les artisans à devenir Thermo Lofteurs
Pour isoler les combles perdus par soufflage dans les règles de l'art, Knauf Insulation invite les artisans à devenir Thermo Lofteurs
12/09/2018 - www.andresudrie.com
Information Presse Février 2017 Pour isoler les combles perdus par soufflage dans les règles de l art, Knauf Insulation invite les artisans à devenir Thermo Lofteurs En 2016, l isolation des combles est arrivée en tête des cinq travaux de rénovation plébiscités par les français. Près de 40% est réalisée en rénovation de combles perdus, une tendance en hausse chaque année. Sur ce marché, l isolation par soufflage de laine minérale représente près de 80%*. Partant de ce constat,...

Certificat - VMZinc
Certificat - VMZinc
11/04/2018 - www.vmzinc.fr
Page 1 sur 1 Certificat Certificate N° 2003/21536.3 AFNOR Certification certifie que le système de management mis en place par : AFNOR Certification certifies that the management system implemented by: Umicore Building Products France SAS pour les activités suivantes : for the following activities: LAMINAGE DE ZINC, TRAITEMENT DE SURFACE, FACONNAGE ET DISTRIBUTION DES PRODUITS POUR LES MARCHES DU BATIMENT. MAITRISE D'OUVRAGE DU TRAITEMENT "IN SITU" DES RESIDUS DES ACTIVITES INDUSTRIELLES PASSEES...

Schako Kg Nachhaltigkeitsbericht 2022 Druck De
Schako Kg Nachhaltigkeitsbericht 2022 Druck De
16/07/2024 - schako.com
Pure competence in air. Nachhaltigkeitsbericht 2022 SCHAKO KG | Sustainability | Page 3 PRÄAMBEL Das Familienunternehmen SCHAKO KG ist seit Jahrzehnten erfolgreich im Bereich Belüftung und Klimatisierung von Gebäuden tätig. In diesem Bereich wurde sehr viel Know-how aufgebaut und viele Patente zeugen von der Innovationskraft des Unternehmens. Wir sehen uns in der Verantwortung gegenüber unseren Mitarbeitern, Kunden, Lieferanten und Anteilseignern das Unternehmen nachhaltig und erfolgreich...