Luminaire Code LFX 3W CL Name LFX-1000 IP20 17x12V3W CL Line AGABEKOV Efficiency 75.73% 101.85 cd/klm Length Length 0.010000 m2 0.020000 m2 0.000200 m2 Asymmetrical 8.70

Measurement Code CLF1414/05-09I Name LFX-1000 IP20 17X12V5WCLEAR Date 11-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 13 mm 10 mm

Lamp Code Number Position Total Flux C=15.00 G=15.00 Height Height

XENON 3W CL 12V 17 530.74 lm

Maximum value

Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° Symmetry Type Measurement Distance Operator Temperature Humidity Notes Line AGABEKOV C.I.E. F UTE 8 0.48 J + 0.28 T

22 mm 20 0.020000 m2 0.000200 m2 0.021825 m2 180 659.26 lm 230.00 V 0.00 A PRC 110

Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° Maximum Gamma Angle Measurement Flux Source Voltage Source Current Photocell

AC 25.00 °C 60.00 % 17 LAMP 12V 5W CLEAR XENON Code XENON 3W CL 12V

Luminaire Lamps Name XENON RIGID LOOP LAMP 3W CL D DIN 5040 B NBN

Flux[lm] 31.22

Pow.[w] 3.0

Qta 17

B21 BZ 7/2.5 / BZ 6

1000mm x 13mm 90 Gamma Angle 180 165 150 135

180 0

100

120 270 C Halfplanes 180.0 90.0 0.0 270.0 105

75

120

50 105 25

90

90

25 75 50 75

ULOR DLOR

Dans la boutique



Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LECX 3W FR Name LECX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 31.79% 107.66 cd/klm Length Length 0.037000 m2 0.022000 m2 0.000814 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-07I Name LECX-1000 IP20 17X12V8.5WFROST Date 23-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 40 mm 37 mm Lamp Code Number Position Total Flux C=0.00 G=25.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU4X 3W CL Name LU4X-1000 IP65 17x12V3W CL Line AGABEKOV Efficiency 62.70% 214.66 cd/klm Length Length 0.033000 m2 0.035000 m2 0.001155 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-12I Name LU4X-1000IP65 17x12V5WCLEAR Date 10-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 35 mm 33 mm Lamp Code Number Position Total Flux C=0.00 G=35.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code ARL T5-1510 80W No Glass Name ARL T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name ARL T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux Asymmetrical Height Height 1 6150.00 lm Rectangular Luminaire Rectangular Luminous Area...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LLN 3W CL Name LLN-1000 IP64 17x12V3W CL Line AGABEKOV Efficiency 31.01% 322.63 cd/klm Length Length 0.060000 m2 0.035000 m2 0.002100 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-01I Name LLN-1000 IP64 17X12V8.5WCLEAR Date 15-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 65 mm 60 mm Lamp Code Number Position Total Flux C=150.00 G=10.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LESI 3W CL Name LESI-1025 IP65 17x12V3W CL Line AGABEKOV Efficiency 30.80% 417.24 cd/klm Length Length 0.090000 m2 0.000000 m2 0.000000 m2 Asymmetrical 8.70 Measurement Code CLF1414/05-10I Name LESI-1025 IP65 17x12V5WCLEAR Date 12-03-2005 Coordinate system C-G Position 1025 mm 1000 mm Width Width 100 mm 90 mm Lamp Code Number Position Total Flux C=0.00 G=0.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code ARLN T5-1510 80W NoGlass Name ARLN T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name ARLN T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AML T5-1510 80W No Glass Name AML T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name AML T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2 90...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LLNAL AB5000K Name LLNAL-1000 AB5000K Line AGABEKOV Efficiency Maximum value 75.21% 1997.90 cd/klm Length Length 0.033250 m2 0.000000 m2 0.000000 m2 Measurement Code LLNAL AB5000K Name Rail LOUVRE NEPTUNE LLN Date 01-00-0098 Coordinate system Position 980 mm 950 mm C-G C=0.00 G=0.00 Width Width 65 mm 35 mm Lamp Code Number Position Total Flux 1 510.00 lm Double Symmetrical Height Height 40 mm 0 0.000000 m2 0.000000 m2 0.008044 m2 90 510.00 lm 0.00 V 0.00 A Rectangular Luminaire...
 


16/02/2025 - www.farrow-ball.com
Résumé en cours de création pour ce fichier PDF

?Alarme technique modulaire 4 zones ?Fonctionne à l'aide de ...
?Alarme technique modulaire 4 zones ?Fonctionne à l'aide de ...
10/03/2012 - kaufelfr.tnb.com
CODE : 521 201 Alarme technique modulaire 4 zones Fonctionne à l'aide de boucles de commande à ouverture ou à fermeture (contact libre de tout potentiel). Bouton poussoir « essai signalisation lumineuse et sonore » Contact de renvoi sonnerie extérieure Renvoi vers coffret répétiteur Renvoi vers module d'extension ATEX 4 ou ATEX 8 (jusqu'à 20 zones maximum). COPYRIGHT 2008 ­ KAUFEL THOMAS & BETTS CARACTERISTIQUES TECHNIQUES Alimentation secteur : Consommation secteur : Batterie Ni Cd...

Novafor - Colas
Novafor - Colas
29/03/2018 - www.sacer.fr
NoticeTechniqueNovaforV3_- 02/10/13 15:49 Page1 N O T I C E T E C H N I Q U E Novafor ® Le renfort des assises Novafor ® permet de réhabiliter d anciennes chaussées peu structurées ou en fin de vie, en créant une nouvelle assise plus performante par retraitement à froid aux liants hydrauliques. La route avanc e NoticeTechniqueNovaforV3_- 02/10/13 15:49 Page2 ® Novafor Le renfort des assises PRINCIPES ET AVANTAGES Novafor ® requiert un matériel spécifique et puissant permettant...

tieback
tieback
09/04/2011 - www.tractel.com
technical sheet ref.: rev. no.: date: page: Safety tieback anchors U-bar models T-4600 2 02/07 1/4 U-bar safety tieback anchors The standard U-bar safety tieback anchors are the economical solution for securing secondary safety lifelines or for equipment tieback. All varieties of standard models are available for every mounting method. All our anchors are designed to meet or exceed all applicable safety codes, regulations and standards where applicable, including FEDOSHA, CALOSHA, ASME/ANSI...

Corniche
Corniche
09/02/2017 - www.leplombfrancais.fr
CORNICHE DE FAIBLE LARGEUR (MAX. 0,25 M DE LARGE) RÉALISATION DE LA TABLE EN PLOMB A EPAISSEUR : l épaisseur minimum est de 1,5 mm LONGUEUR : la longueur le plus couramment utilisée est 1 m par élément. Ne jamais dépasser 1,50 m. DÉTERMINER LA LARGEUR DE LA BANDE DE PLOMB : Largeur des bandes de filets disponibles dans notre gamme : 300-330-350 mm Schéma A : pince + retombée + largeur de la corniche + remontée soit : 25 mm + largeur de la retombée + largeur de la corniche + 100 mm Schéma...

Guide de choix Géomembranes
Guide de choix Géomembranes
28/06/2013 - www.siplast.fr
Géomembranes Guide de choix Géomembranes Guide de choix Une géomembrane adaptée à votre ouvrage Le choix d une géomembrane pour un ouvrage donné dépend de nombreux ­p aramètres. Les tableaux de cette page les présentent par famille, accompagnés de la recommandation Siplast en termes de solutions produits. Chaque ouvrage est spécifique et la ­p remière étape d un dimensionnement est de hiérar­chiser ces critères afin de pouvoir déterminer la nature de la géomembrane à...